SECTION 5 - JLG CONTROL SYSTEM
3121133
– JLG Lift –
5-5
NOTE:
Refer to the appropriate Machine Personality Set-
tings Table, and the Machine Setup Table in the JLG
Service Manual for the default settings.
Password 33271 will give you access to level 1,
which will permit you to change all machine person-
ality and/or machine setup settings.
CHANGING THESE SETTINGS MAY ADVERSELY AFFECT THE
PERFORMANCE OF YOUR MACHINE.
The flash code is indicated on the face of the platform
control box as shown:
NOTE:
Flash codes are also displayed on the handheld ana-
lyzer. For descriptions see Table 5-1, Fault Code
Listing.
NOTICE
IT IS A GOOD PRACTICE TO AVOID PRESSURE-WASHING ELEC-
TRICAL/ELECTRONIC COMPONENTS. SHOULD PRESSURE-
WASHING BE UTILIZED TO WASH AREAS CONTAINING ELECTRI-
CAL/ELECTRONIC COMPONENTS, JLG INDUSTRIES, INC. REC-
OMMENDS A MAXIMUM PRESSURE OF 750 PSI (52 BAR) AT A
MINIMUM DISTANCE OF 12 INCHES (30.5 CM) AWAY FROM THESE
COMPONENTS. IF ELECTRICAL/ELECTRONIC COMPONENTS
ARE SPRAYED, SPRAYING MUST NOT BE DIRECT AND BE FOR
BRIEF TIME PERIODS TO AVOID HEAVY SATURATION.
SYSTEM
FAULT
1705189A