SECTION 6 - GENERAL ELECTRICAL INFORMATION & SCHEMATICS
6-6
– JLG Sizzor –
3121133
Assembly
Check to be sure the wedge lock is in the open, or as-shipped, position (See Figure 6-6. Connector Assembly (1 of 4)). Pro-
ceed as follows:
Figure 6-6. Connector Assembly (1 of 4)
1.
To insert a contact, push it straight into the appropriate circuit cavity as far as it will go (See Figure 6-7. Connector
Assembly (2 of 4)).
2.
Pull back on the contact wire with a force of 1 or 2 lbs. to be sure the retention fingers are holding the contact (See Fig-
ure 6-7. Connector Assembly (2 of 4)).
3.
After all required contacts have been inserted, the wedge lock must be closed to its locked position. Release the lock-
ing latches by squeezing them inward (See Figure 6-8. Connector Assembly (3 of 4)).
4.
Slide the wedge lock into the housing until it is flush with the housing (See Figure 6-9. Connector Assembly (4 of 4)).
Figure 6-7. Connector Assembly (2 of 4)