SECTION 1 - SAFETY PRECAUTIONS
1001070465
LIFTPOD by JLG
1-6
rying up to 50,000 volts. One foot (0.3m) additional clear-
ance is required for every additional 30,000 volts or less.
• The minimum safe approach distance may be reduced if
insulating barriers are installed to prevent contact, and if
the barriers are rated for the voltage of the line being
guarded. These barriers shall not be part of
(or attached
to)
the machine. The minimum safe approach distance
shall be reduced to a distance within the designed work-
ing dimensions of the insulating barrier. This determina-
tion shall be made by a qualified person in accordance
with employer, local, or governmental requirements for
work practices near energized equipment.
DO NOT MANEUVER MACHINE OR PERSONNEL INSIDE PROHIBITED
ZONE (MAD). ASSUME ALL ELECTRICAL PARTS AND WIRING ARE
ENERGIZED UNLESS KNOWN OTHERWISE.
Tipping Hazards
• Only elevate the platform on a firm and level surface.
• Check that the two wheels and the two adjustable feet are
in contact with the ground prior to using the machine.
Adjust the front feet to eliminate any base frame move-
ment and check the bubble level indicates level prior to
use.
• Ensure castor wheels are locked (if equipped).