SECTION 7 - BASIC ELECTRICAL INFORMATION & SCHEMATICS
3121200
7-3
Current Measurement
• Set up the meter for the expected current range
• Be sure to connect the meter leads to the correct jacks
for the current range you have selected
• If meter is not auto ranging, set it to the correct range
(See multi meter’s operation manual)
• Use firm contact with meter leads.
7.3
CHECKING SWITCHES
Basic Check
The following check determines if the switch is functioning
properly, not the circuit in which the switch is placed. A switch
is functioning properly when there is continuity between the
correct terminals or contacts only when selected.
1.
De-energize the circuit.
2.
Isolate the switch from the rest of the circuit if possible.
If not possible, keep in mind it may affect readings.
3.
Access the terminals to the switch.
4.
If the switch has two terminals:
a. Measure resistance across the terminals.
b. Change the switch position.
c. Measure resistance again with the leads in the same
positions. If the meter was reading short, it should
read an open. If the meter was reading open it
should read short.
5.
If the switch has more than two terminals, consult the
schematic or switch diagram to determine what termi-
nals will be connected. The test is similar to testing a
switch with two terminals.
a. Place one meter lead on the common contact and
the other on a different contact in the same circuit.
b. Cycle through all positions of the switch. The meter
should read short only when the switch connects
the two terminals and open otherwise.
c. If the switch has more than one common contact
repeat the process for that circuit.
Figure 7-4. Current Measurement (DC)
Summary of Contents for T500J
Page 1: ...Service and Maintenance Manual Model T500J PN 3121200 July 25 2018 Rev I AS NZS...
Page 2: ......
Page 16: ...xii 3121200 LIST OF TABLES TABLE NO TITLE PAGE NO This page left blank intentionally...
Page 36: ...SECTION 2 GENERAL 2 8 3121200 NOTES...
Page 143: ...SECTION 3 CHASSIS TURNTABLE 3121200 3 107 Figure 3 45 Battery Charger Schematic...
Page 234: ...SECTION 5 BASIC HYDRAULIC INFORMATION SCHEMATICS 5 60 3121200 NOTES...
Page 246: ...SECTION 6 JLG CONTROL SYSTEM 6 12 3121200 Figure 6 5 System Test Flow Chart Platform Tests...
Page 304: ...SECTION 7 BASIC ELECTRICAL INFORMATION SCHEMATICS 7 32 3121200 NOTES...
Page 305: ......