BATTERY - CHARGER
4
4
B-
EMB-MP model
- Display panel :
a.
Battery indicator connected (green)
b.
Indicator battery in final charging phase (yellow)
c.
Indicator charge completed (green)
d.
Fault indicator (red)
e.
Circuit breaker
- Battery charge :
- Once the charger is connected to the power
supply, all the leds will flash for a short time,
indicating the card is on automatic test phase.
- If all the connections are correct, the green led
(a) lights up and the charge starts automatically
after 5 seconds.
- The charging phase starts, the green led (a)
flashes slowly (Frequency = 1 second) during
the duration of the charge.
- Once the final charging phase has been reached
(approximately 80%), led (a) still flashes and
led (b) lights up fixed.
- At the end of the charging process, both leds
(a) and (c) are on fixed.
- Equalization charge :
- When the charger is doing an equalization
charge:
ç
both leds (a) and (c) flash slowly.
ç
Led (b) is lit fixed.
- Fault indicator :
- Should the transformer overheat, the red led
(d) flashes quickly (Fréqency = 0.2 second).
- If the battery does not reach 2.4V/cell after a
10 hour charge, the charging process stops
and the red led (d) lights up.
It is advised to have either the charger or the battery
checked by a technician.
a
b
c
d
e
C-
MT-S model
- Display panel :
a.
Battery indicator connected (green)
b.
Indicator battery in final charging phase (yellow)
c.
Indicator charge completed (green)
d.
Fault indicator (red)
e.
Circuit breaker
- Battery charge :
- Once the battery is connected, all the leds will
flash for a short while, indicating the card is in
the automatic test phase.
- If all the connections are correct, the green led
(a) will light up and the charge will start
automatically after 5 seconds.
- The charging process starts, the green led (a)
flashes for the duration of the charging process.
- Once the voltage reaches 2,4 V/cell., indicated
by the yellow led (b), the internal meter starts
the last 3 hours of charge.
- At the end of the charging process (green led
(c) lit), the charger disconnects itself
automatically.
- Fault indicator :
- In case the transformer overheats, the red led
(d) flashes quickly.
- If the battery does not reach a 2.4 V/cell voltage
after 10 hours of charge, the charging process
will stop and the red led (d) will light up.
It is recommended to have either the charger
or the battery checked by a technician.
- In case of a power cut, the charger stops and
the green led (a) is lit.
- the led (d) flashes as long as the charger is
not connected to the power supply.
a
b
c
d
Summary of Contents for TOUCAN 1010
Page 2: ......
Page 3: ...3 Models Edition 04 2006 Toucan 1010 MA0235 02 Models Toucan1010 _____ Toucan1010 I _____...
Page 18: ...Thispageintentionallyleft blank CORRECTIVE ACTION REQUEST...
Page 24: ...Thispageintentionallyleft blank CORRECTIVE ACTION REQUEST...
Page 36: ...Thispageintentionallyleft blank CORRECTIVE ACTION REQUEST...
Page 38: ...Thispageintentionallyleft blank CORRECTIVE ACTION REQUEST...
Page 80: ...Thispageintentionallyleft blank CORRECTIVE ACTION REQUEST...
Page 84: ...Thispageintentionallyleft blank CORRECTIVE ACTION REQUEST...
Page 85: ...85 Models Edition 04 2006 Toucan 1010 LUBRICATION 8 8 1 Lubrication points TABLE OF CONTENTS...
Page 86: ...Thispageintentionallyleft blank CORRECTIVE ACTION REQUEST...