SECTION 6 – GENERAL SPECIFICATIONS & OPERATOR MAINTENANCE
31210088
– JLG Lift –
6-11
As with any wet cell battery, check the electrolyte level of the
batteries often, using the floats in the center of each cell filling.
Figure 6-4. Level Indicators
1.
Float does not emerge - Insufficient Level
2.
Float emerges - Correct Level
Add distilled water only when required.
ADD ONLY DISTILLED WATER TO BATTERIES. FILL BATTERIES ONLY
AFTER CHARGING (DURING CHARGE, ELECTROLYTE LEVEL INCREASES
AND CAN OVERFLOW).
- Fill the
reservoir (1)
with distilled water.
- Depress and hold the filling
pump activation button (2)
.
- Release the button when the
flow indicator (3)
slows down.
- Ensure the level is correct in each cell.
Figure 6-5. Adding Water to Batteries
1.
Water Reservoir
2.
Pump Activation Button
3.
Flow Indicator
4.
Filter