Models
Revision 03-2012
102
Toucan 1210
Toucan 1310
ELECTRICAL SYSTEM
4
4
NOTE
The contact is correctly inserted after going
through a notch.
Order of insertion :
Green / yellow wire
Ô
Not used
Wire n° 26
Ô
housing n° 26
... / ...
Wire n° 1
Ô
housing n° 1
4. Push in the contact red retaining plate.
NOTE
Pinch the holding clips of the blocks to
facilitate insertion.
TERMINAL BLOCK LOCKING MUST BE DONE
WITHOUT EFFORT !
Check the red plate is correctly inserted in
the black connector body.
If the terminal is hard or impossible to push in :
- check the contacts are correctly inserted in
their housing with rounded pliers. (see below)
5. Closing the connector.
- screw in the rear part of the connector while
holding the red terminal block in place (a).
- check that the orientation of the dummy studs
is similar to the one shown in picture below
(b).
- lock the elbow (if present) (c).
- push in the cable towards the inside of the
connector (d).
- tighten the gland (e).
- ensure the contacts are flush with the top of
the connector.
Faulty connector
If impossible to correctly wire the connector, remove
the red retaining plate : locating sprockets should not
be broken.
è
è
Dummy studs
a
c
e
d
b r o k e n
sprocket