4.5 Speed electronic controller
The motor speed controller installed on the platform
enables the variation of the rotation speed of the main
hydraulic power unit, therefore the modification of the
speed of the work platform movements.
The controller presents 8 programmable speeds :
- Six variable speeds.
- Two fixed speeds (only one is used).
The controller parameters can only be adjusted with
an appropriate SEVCON calibrator (Ref. : 920021).
No parameter or variable can be modified
without prior written approval from the
elevating work platform manufacturer.
Controller variable settings
1- Position the control panel selector either to
"platform controls" or "ground controls". Ensure
the lower emergency stop switch is not
activated.
2- Connect the calibrator to the controller.
When the calibrator is connected to the controller,
the operating time is displayed on the screen.
- Press on the arrow to display the operating
hours.
- Press on the arrow
to display 1000's of
operating hours.
Example :
For an operating time of 1436 hours 27 minutes and
20 seconds, the screen will display :
- Display on connection to the calibrator : 27.2
(meaning 27 minutes and 20 seconds).
- Button depressed, display : 436 (meaning
436 hours).
- Button depressed, display : 1 (meaning 1000
hours).
NOTE
The meter is reset to 0 after 65500 hours of
operation.
3- Press on the "
select
" button. A red LED lights
up opposite the first parameter : "
speed1
". The
parameter value is displayed on the screen.
Press on the arrow to increase the value of
this parameter.
Press on the arrow to decrease the value of
this parameter.
Each time the "
select
" button is depressed, a red LED
lights up opposite the next parameter, the value of this
parameter is displayed on the screen and can be
modified with the and buttons.
DANGER
To (-) battery
To (+) battery
To
(-)
power unit Insulated
from (+) and (-) battery
Diagnostic
LED
Calibrator
Available parameters for "pump" controller