Toucan 1210
Toucan 1310
ELECTRICAL SYSTEM
4
4
Fuses for time delay module
Toucan 1310
L
OCATION
: Inside the emergency control panel.
F
UNCTION
: Protection of the coil supply circuit for :
[MAV]
F1
[MAR]
F2
[DV1]
F3
[HI/LO]
F4
[EVF]
F5
[DB]
F6
[DM]
F7
F1, F2, F3, F5, F6, F7 :
Quick acting pluggable fuses
type ATO 1A.
F4
: Quick acting pluggable fuse type ATO 2A.
Toucan 1210
Equiped with resetable fuses. See § 4.6.3.
4.6.3. Resetable fuses (PolySwitch®)
Principle of operation
These components, welded on the electronic cards
of the control circuit are acting as protections
dedicated to parts of the circuit.
This type of component is a plastic composite
charged with carbon particles that, under the influence
of a fault current, are submitted to a temperature
increase resulting in a separation of these particles
and thus increasing greatly the internal resistance of
the component.
This great temperature increase may help in locating
a cut out component.
The component temperature under the
influence of a fault current may reach 125°C.
When the fault current disappears, the component's
initial capacities are restored automatically after
approximately 30 seconds.
L
OCATION
: Electronic card in the platform control panel.
1.
PolySwitch® 0,25A
F
UNCTION
: Protection of the supply circuit to the
controls module.
2.
PolySwitch® 1,85A.
F
UNCTION
: Protection of the supply circuit to the coil
[EVI] (platform inclination - see § 3.14).
3.
PolySwitch® 1,85A.
F
UNCTION
: Protection of the supply circuit to the coil
[EVR] (platform rotation - see § 3.15).
F1
F2
F3
F4
F5
F6
F7
DANGER