87
Models
Revision 03-2012
Toucan 1210
Toucan 1310
ELECTRICAL SYSTEM
4
4
Detection controls in neutral :
Drive movements
- When the movement control joystick for drive
and/or a steering control button is actuated :
ç
Inputs [N1] and [N2] are in the same state
:
- 0 to 4 V if the control has not been
authorized- Led [LD1] off.
- 24 V if the control has been authorized -
Led [LD1] on.
ç
LED [LD2] lights up.
ç
LED [LD3] goes off.
Structure movements (except platform levelling)
- When a structure movement control switch is
actuated :
ç
Inputs [N3] and [N4] are in the same state
:
- 0 to 4 V if the control has not been
authorized- Led [LD1] off.
- 24 V if the control has been authorized- Led
[LD1] on.
ç
LED [LD4] lights up.
Platform levelling movements
- When the levelling control movement is actuated
:
ç
Inputs [N5] and [N6] are in the same state
:
- 0 to 4 V if the control has not been
authorized- Led [LD1] off.
- 24 V if the control has been authorized- Led
[LD1] on.
ç
LED [LD6] lights up.
Combination of movements
- If at least two of the Input groups [N1 - N2], [N3
- N4] and [N5 - N6] are in the same condition :
ç
The control is not authorized or the
authorization of the control in progress is
cancelled (Led [LD1] goes out in the case
where the authorization is cancelled).
ç
Output [E8] goes to 24 V ("Pump Inhibit"
function of the controller actuated - see §
4.5 - and orange indicator on).
ç
Led [LD5] lights up (indicates the state of
the output [E8]).
Detection of discharge indicator power
cut
When the power is cut out by the discharge indicator,
the input [E10] is no longer supplied : the controls
can no longer be enabled [RESET]. Input [E10] must
be supplied before input [E4] for the controls to be
authorized. The reset push button on the platform
control panel allows to "force" entry [E10] to 24 V ; it
must be actuated and held before the enable pedal is
depressed.
Description of entries / outputs of the module :
Inputs
Outputs
Pin n°
Function
Remarks
E1
15
24V
E2
16
Supply 0 V
E3
11
Auxillary
Not used
E4
12
Enable pedal (+)
E5
17
12 Vcc regulated output
E6
13
Supply "Enable" relay [K1] (-)
E7
4
Supply "Enable" relay [K1] (+)
Not used
E8
3
Supply "Pump Inhibit" function
E9
2
Reset module 0 (V)
Not used
E10
1
Reset module (24 V)
N1
18
N2
6
N3
19
N4
7
N5
20
N6
8
N7
5
Movement selection
Not used
C1
23
Movement detection
Not used
C2
24
Accelerator 100%
Not used
C3
25
Supply to speed reduction relay (-)
Not used
Detection drive movements in neutral
Detection structure movements in neutral (except levelling)
Detection platform levelling movements in neutral