SECTION 2 - SERVICE PROCEDURE
31215460
2-7
Temperature Sensor Test - 2nd Generation
1.
Disconnect all temperature sensor connectors
(J1, J2, J3) from the BMS.
2.
Check voltage between negative terminal and
sensor pin on connectors
a.
If V=0: OK
b.
If V
≠
0: Bad Insulation
3.
Check sensor resistance values
10000 Ohm at 77°F (25°C)
15000 Ohm at 59°F (15°C)
38V/76V with 3rd Generation BMS
The 3rd Generation BMS can be arranged with one or
two electronic cards. The 38V and 76V BMS for 3rd gen-
eration are interchangeable with software update. The
3rd Generation BMS manages all the functions as
described in the 1st Generation BMS.
MAF11500
MAF16860
BMS Connection
1st - 2nd Gen
Temperature
Sensor
View AA
Temperature
Sensor
BMS Connection
3rd Gen
View BB
MAF12850
Figure 2-5. 38 Volt BMS - 3rd Generation
MAF12860
Figure 2-6. 76 Volt BMS - 3rd Generation