12
CHANGING THE BEARING HOUSING SQ2 - SQ3
1. Place the bowl upside down on the flat surface.
2. Turn the Allen key anti clockwise and remove the 3 bolts, (allen keys provided)
3. Remove the old housing and place back in the box the new housing was sent in and
return to JM Posner LTD.
4. Clean the basin thoroughly (remove any Grease or chocolate)
5. Take the new Housing and Match the hole “A” on the housing to the “A” marking on
the Basin.
6. Hand tighten all 3 bolts first.
7. With the Allen key turn clockwise until tight.