background image

 

 

1

OUTDOOR SPA 

 
 
 

SPA-318 

 
 
 

                               

PROGRAMMING INSTRUCTIONS 

 
 

 

 
 
 
 
 
 
 
 
 

Summary of Contents for SPA-318

Page 1: ...1 OUTDOOR SPA SPA 318 PROGRAMMING INSTRUCTIONS ...

Page 2: ... Set switch C F Blower on Off Temperature Mode Shift OPEN Volume down Open Light from the bottom on Off MEM Radio memory Lock Surf Water pump 1 on Off CLOSE Radio searching Close PUMP2 Surf Water pump 1 on Off OZONE Circulation cleaning set of ozone On Off PUMP3 Setting Of circulation Cleaning Surf Water pump 3 on Off HEAT Preheat setting Heater On Off TEMP Temperature setting Note Function of but...

Page 3: ...so as well as the pre heat and circulation cleaning AM AM Fig 3 Normal temperature Fig 4 Sensor open circui or short circuit 2 Lock Operation The lock will start work by pressing MEM Button in the status of power off or no pressing operation lasting above 30 minute In the status of Locked press the button MEM twice the lock will be unlocked and the word LOCKED will disappear 3 Time setting operati...

Page 4: ...n the system enter into time setting of Circulation cleaning the setting time will flash on the LCD this time is the Circulation cleaning time which will start at this moment only MIN and HOUR are available to change the time It will add 1 minute when pressing MIN each time and the minutes could be added the continually when pressing the MIN without stop The adjustment range is 0 59 It will add 1 ...

Page 5: ...on Press OZONE can turn on OZONE synchronization 5 When everything is setting well Press PUMP3 again the system will quit the Circulation cleaning setting status Notice 1 all setting of Circulation cleaning must be in Power OFF status 2 Circulation PUMP and OZONE are not working while all setting time 5 Pre heating setting Only one pre heating setting is allowed each day The LCD can show clearly i...

Page 6: ...ill add 10 minutes by pressing MIN each time and it will add 1 hour when pressing HOUR each time please note that the maximum of continual time is 19 hours and 50 minutes When you set up well of the continual time you could go on to the next step 4 Press SET VOL again to the temperature setting of pre heating It will show SET label on the LCD panel press TEMP and button could change the temperatur...

Page 7: ... the circulation pump and ozone If it is on will work at the same time Then LCD will show count down time In the circulation cleaning process till cont down time finished the circulation cleaning will be turned off automatically by system or by pressing ON OFF key intentionally 8 Operation to Power ON OFF Pressing the key will enter from UONU to UOFFU or UOFFU to UONU At the same time the LCD will...

Page 8: ...essing the key MEM continually will memorize the present radio frequency in different channel The channel of max is 10 Name of channel is 0 9 Ⅵ The volume can be changed by pressing key SET VOL OPEN 11 Operation to Pump KEY of Pump1 are control surf pump1 Key of Pump2 are control surf pump2 Key of Pump 3 are control surf pump3 Pump3 are circulation pump at the same time The LCD will show when circ...

Page 9: ...e mode of Fahrenheit Celsiur temperature 17 When there is no water in the bathtub water pumps blower and constant temperature system will not start up However the corresponding signal on the LCD will flash 18 Frozen preventing control The heater circulation pump will on when water temperature is under 5 And will off when up 10 The function is effective when power on 4 Electric parameters 1 Perform...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...OM ACN ACN P3 P2 NO COM NC NO COM PUMP2 DVD TV HEAT ACN ACN P1 220VAC NC NO COM COM NO NC PUMP3 BLOWER CD SPK L SPK R LIGHT SENSOR LEAD IN WATER SWITCH WATER PIN POWER INPUT Creepage protector 100A switch PUMP2 CONNECTION FACE DVD TV ACN ACL HEAT PUMP1 MAIN BOARD ...

Reviews: