background image

 

 

8

by system or by pressing   

ON/OFF

 key intentionally

 

 

(8) Operation to Power ON/ OFF 

Pressing the key 

  will enter from 

U

ON

U

 to 

U

OFF

U

 or 

U

OFF

U

 to 

U

ON

U

  At the same time

  the LCD will show 

whether the power is on or off

 

AM

OFF

               

AM

OFF

 

Fig

9

  OFF                                                Fig

10

 ON 

 

(9) Operation to Temperature setting 

In the status of 

U

Power-on

U

 and 

HEATER

 is working 

The temperature setting can operate

 only 

key 

TEMP

are available

  It will add 

1

℃ when pressing “

TEMP

 and the 

temperature could be 

added continually  till 45

 when pressing the 

TEMP

without stop

At this time 

, when pressing 

TEMP

 angin

and the 

temperature could return 25

 

The range of adjustment is 25~45

 

 

 

(10)Operation Radio & CD: 

AM

PUMP3

 

Fig

11

  Radio frequency is 105.2 MHZ

Save the present frequency to channel 3 (Save channel)   

or Exchange the frequency form channel 3 to the present (Searching channel) 

)

Key 

AUDIO

CD

  is the ON/OFF key for radio and CD

and it is only available in the status of power on. 

The first pressing is turning on the radio

the second pressing will turn off the radio and turn on the CD at the same 

time

and the third

will turn off the radio and CD simultaneous

 

Ⅱ)、

LCD will show present frequency and volume of the radio after turning on the radio

 

Ⅲ)、

In the working of radio

  The volumle of the present radio frequency

 

can be changed by pressing

 

MIN

&

HOUR

 

 

Ⅳ)、

Pressing the key 

CLOSE

 will take out the memorized radio frequency

Pressing the key

CLOSE

    continually will take out the memorized radio frequency from channels will be saved at present 

channel by pressing this key continually

If none of the channel

 LCD will display 

---

。 

Ⅴ)、

Press the key

MEM

 ”

 could memorize the present radio frequency

 Pressing the key

MEM

 ”

    continually will memorize the present radio frequency in different channel

  The channel of max 

Summary of Contents for SPA-8028

Page 1: ...1 Outdoor spa SPA 8028 PROGRAMMING INSTRUCTIONS ...

Page 2: ...Hour CD RADIO Radio CD Input On Off SET VOL Volume up Set switch C F Blower on Off Temperature Mode Shift OPEN Volume down Open Light from the bottom on Off MEM Radio memory Lock Surf Water pump 1 on Off CLOSE Radio searching Close PUMP2 Surf Water pump 1 on Off OZONE Circulation cleaning set of ozone On Off PUMP3 Setting Of circulation Cleaning Surf Water pump 3 on Off HEAT Preheat setting Heater...

Page 3: ... halt and the LCD will show the present time and temperature It will show E1 if the sensor is open short circuit When part of radio frequency showed it indicates that the status of the system is power off so as well as the pre heat and circulation cleaning AM AM Fig 3 Normal temperature Fig 4 Sensor open circui or short circuit 2 Lock Operation The lock will start work by pressing MEM Button in th...

Page 4: ...P3 and enter to Circulation cleaning setting status and the LCD flashes of 2 Press OPEN can turn on Circulation cleaning setting status by opposite if press CLOSE it will turn off the Circulation cleaning And this time on LCD will not flash When the system enter into time setting of Circulation cleaning the setting time will flash on the LCD this time is the Circulation cleaning time which will st...

Page 5: ... When you set up well of the continual time you could go on to the next step 4 Press SET VOL again to turn on or off OZONE synchronization OZONE of LCD will flash This is mean OZONE is turned off synchronization Press OZONE can turn on OZONE synchronization 5 When everything is setting well Press PUMP3 again the system will quit the Circulation cleaning setting status Notice 1 all setting of Circu...

Page 6: ...ite if press CLOSE it will turn off the pre heating and at this time ONOFF on LCD will turn to ON and will not flash if press CLOSE to turn off pre heating LCD will display OFF which do not flash there When the system enter into time setting of pre heating the setting time will flash on the LCD this time is the pre heating time which will start at this moment only MIN and HOUR are available to cha...

Page 7: ...on PUMP and HEATER are not working while all setting time 6 Pre heating When the time of real time and pre heating time is consistent meanwhile there is water in the bathtub and the pre heating button is on the system will start the pre heating and circulation pump and auto constant temperature system will work at the same time Then LCD will show count down time the two middle spot will not flash ...

Page 8: ...cy form channel 3 to the present Searching channel Ⅰ Key AUDIO CD is the ON OFF key for radio and CD and it is only available in the status of power on The first pressing is turning on the radio the second pressing will turn off the radio and turn on the CD at the same time and the third will turn off the radio and CD simultaneous Ⅱ LCD will show present frequency and volume of the radio after tur...

Page 9: ...constant temperature heating system 2 After the startup of constant temperature heating circulation pump will be running all the while 3 For example if the temperature is set at 35 when the water temperature reaches or exceeds 36 the heater will be turned off automatically and the circulation pump will stop after 5 second If PUMP3 is turn off However when the water temperature reach or lower than ...

Page 10: ...e 200MΩ Water resistance grade IPX5 Electric shock resistance first grade 2 Output loading index Heater AC220V 3KW x 1 Surf Water pump AC220V 2 HP x 3 water pump AC220V 1HP x 1 Air pump AC220V 0 7kw x 1 spa light AC12V 5W x 2 Ozone AC12V 15W x 1 water pump AC220v 0 25HP x 1 Radio 1 Frequency Range FM 87 0 108 0MHz 2 Maximum Output Power 10W 3 Speaker 8Ωdamp proof speaker ...

Page 11: ...11 ...

Page 12: ...12 ...

Page 13: ...OM ACN ACN ACN P2 P3L P3 NO COM NC NO COM PUMP3 PUMP2 P12 HEAT ACN ACN ACN P11 220VAC NC NO COM COM NO NC COM NO NC PUMP3L BLOWER CD SPK L SPK R LIGHT SENSOR LEAD IN WATER SWITCH WATER PIN POWER INPUT Creepage protector 100A switch PUMP3 Circulation CONNECTION FACE PUMP2 DVD ACN ACL HEAT PUMP11 MAIN BOARD ...

Reviews: