9
is 10
,
Name of channel is 0-9
。
Ⅵ)、
The volume can be changed by pressing key
“
SET
VOL+
”
&
“
OPEN
”。
(11)Operation to Pump :
KEY of “Pump1” are control surf pump1 & surf pump2 , Key of “Pump2” are for water Column &
waterfall pump(water Column light is working synchronization). Key of “Pump 3” are only for pump3 When turn on
pump 3
,
LCD will show
,
in spite of the heating and circulation is on or off
。
T
he LCD will show
sequently
。
When pump3 off and heating
(
including pre-heating
)
and circulation start
,
PUMP1 & PUMP2 will auto off when working 2 hour later
。
(12) Operation to Ozone
:
The ozone could be started up in the status of circulation cleaning
。
Press the key
“
OZONE
”
to turn on/off the ozone
。
After the startup of ozone
,
if the user would not
change the working status of ozone
,
it will be turned off automatically 5 minutes later
。
(13) Operation to Bottom lamp
:
“
”
controlling the ON/OFF of the lamp in the bottom of the bathtub
。
(14) Operation to Constant temperature heating
:
1)
、
When the pre-heating time is up
(
If the pre-heating has turned on
)
or press the
“
HEAT
”
will
also start constant temperature heating system
。
2
)、
After the startup of constant temperature heating
,
circulation pump will be running all the while
。
3)
、
For example
:
if the temperature is set at 35
℃,
when the water temperature reaches or exceeds 36
℃,
the heater will be turned off automatically and the circulation pump will stop after 5 second
(
If PUMP3 is turn
off
)。
However
,
when the water temperature reach or lower than 34
℃,
the heater will start up
。
4)
、
When the temperature sensor is open/short (LCD shows ”E1”)
,
the auto temperature control system
will not be available
,
Turning on/off the constant temperature system will turn on/off the heater
。
(15) Operation to blower
:
there is a key
“
C
F/
”
controlling the on/off of blower
。
BLOWER will auto off when working 2 hour later
。
(16)Fahrenheit & Celsiur temperature shift
:
In the status of
“
U
Power off
U
”,
pressing the key
“
C
F/
”
can change the mode of
Fahrenheit & Celsiur
temperature
。
(17)
When there is no water in the bathtub
,
water pumps
、
blower and constant temperature system will not
start up
。
However
,
the corresponding signal on the LCD will flash
。
(18) Frozen preventing control
:
The heater & circulation pump will on when water temperature is under 5
℃,
And will off when up 10
℃。
The
function is effective when power on
。
4.Electric parameters
Summary of Contents for SPA-8028
Page 1: ...1 Outdoor spa SPA 8028 PROGRAMMING INSTRUCTIONS ...
Page 11: ...11 ...
Page 12: ...12 ...