background image

 

 

9

is 10

Name of channel is 0-9

 

Ⅵ)、

The volume can be changed by pressing key 

SET

VOL+

&

OPEN

”。

 

 

(11)Operation to Pump : 

KEY of  “Pump1”  are control surf pump1 & surf pump2 , Key of “Pump2” are for water Column & 

waterfall pump(water Column light is working synchronization). Key of “Pump 3” are only for pump3 When turn on 

pump 3

 LCD will show

in spite of the heating and circulation is on or off

T

he LCD will show 

sequently

When pump3 off and heating

including pre-heating

  and circulation start

 

PUMP1 & PUMP2 will auto off when working 2 hour later

 

(12) Operation to Ozone

 

The ozone could be started up in the status of circulation cleaning

 

Press the key 

OZONE

  to turn on/off the ozone

  After the startup of ozone

  if the user would not 

change the working status of ozone

  it will be turned off automatically 5 minutes later

 

 

(13) Operation to Bottom lamp

 

 

controlling the ON/OFF of the lamp in the bottom of the bathtub

 

 

(14) Operation to Constant temperature heating

   

1)

  When the pre-heating time is up 

If the pre-heating has turned on

  or press the 

HEAT

 will 

also start constant temperature heating system

 

2

)、

After the startup of constant temperature heating

  circulation pump will be running all the while

 

3)

For example

if the temperature is set at 35

℃,

  when the water temperature reaches or exceeds 36

℃,

  the heater will be turned off automatically and the circulation pump will stop after 5 second

If PUMP3 is turn 

off

)。

    However

  when the water temperature reach or lower than 34

℃,

  the heater will start up

 

4)

  When the temperature sensor is open/short (LCD shows ”E1”)

  the auto temperature control system 

will not be available

  Turning on/off the constant temperature system will turn on/off the heater

 

 

(15) Operation to blower

   

there is a key

C

F/

controlling the on/off of blower

 

BLOWER will auto off when working 2 hour later

 

 

(16)Fahrenheit & Celsiur temperature shift

 

In the status of

U

Power off

U

”,

pressing the key

C

F/

  can change the mode of 

Fahrenheit & Celsiur 

temperature 

 

 

(17)

 When there is no water in the bathtub

 water pumps

  blower and constant temperature system will not 

start up

 However

  the corresponding signal on the LCD will flash

 

 

(18) Frozen preventing control

 

The heater & circulation pump will on when water temperature is under 5

℃,

And will off when up 10

℃。

The 

function is effective when power on

 

4.Electric parameters

 

Summary of Contents for SPA-8028

Page 1: ...1 Outdoor spa SPA 8028 PROGRAMMING INSTRUCTIONS ...

Page 2: ...Hour CD RADIO Radio CD Input On Off SET VOL Volume up Set switch C F Blower on Off Temperature Mode Shift OPEN Volume down Open Light from the bottom on Off MEM Radio memory Lock Surf Water pump 1 on Off CLOSE Radio searching Close PUMP2 Surf Water pump 1 on Off OZONE Circulation cleaning set of ozone On Off PUMP3 Setting Of circulation Cleaning Surf Water pump 3 on Off HEAT Preheat setting Heater...

Page 3: ... halt and the LCD will show the present time and temperature It will show E1 if the sensor is open short circuit When part of radio frequency showed it indicates that the status of the system is power off so as well as the pre heat and circulation cleaning AM AM Fig 3 Normal temperature Fig 4 Sensor open circui or short circuit 2 Lock Operation The lock will start work by pressing MEM Button in th...

Page 4: ...P3 and enter to Circulation cleaning setting status and the LCD flashes of 2 Press OPEN can turn on Circulation cleaning setting status by opposite if press CLOSE it will turn off the Circulation cleaning And this time on LCD will not flash When the system enter into time setting of Circulation cleaning the setting time will flash on the LCD this time is the Circulation cleaning time which will st...

Page 5: ... When you set up well of the continual time you could go on to the next step 4 Press SET VOL again to turn on or off OZONE synchronization OZONE of LCD will flash This is mean OZONE is turned off synchronization Press OZONE can turn on OZONE synchronization 5 When everything is setting well Press PUMP3 again the system will quit the Circulation cleaning setting status Notice 1 all setting of Circu...

Page 6: ...ite if press CLOSE it will turn off the pre heating and at this time ONOFF on LCD will turn to ON and will not flash if press CLOSE to turn off pre heating LCD will display OFF which do not flash there When the system enter into time setting of pre heating the setting time will flash on the LCD this time is the pre heating time which will start at this moment only MIN and HOUR are available to cha...

Page 7: ...on PUMP and HEATER are not working while all setting time 6 Pre heating When the time of real time and pre heating time is consistent meanwhile there is water in the bathtub and the pre heating button is on the system will start the pre heating and circulation pump and auto constant temperature system will work at the same time Then LCD will show count down time the two middle spot will not flash ...

Page 8: ...cy form channel 3 to the present Searching channel Ⅰ Key AUDIO CD is the ON OFF key for radio and CD and it is only available in the status of power on The first pressing is turning on the radio the second pressing will turn off the radio and turn on the CD at the same time and the third will turn off the radio and CD simultaneous Ⅱ LCD will show present frequency and volume of the radio after tur...

Page 9: ...constant temperature heating system 2 After the startup of constant temperature heating circulation pump will be running all the while 3 For example if the temperature is set at 35 when the water temperature reaches or exceeds 36 the heater will be turned off automatically and the circulation pump will stop after 5 second If PUMP3 is turn off However when the water temperature reach or lower than ...

Page 10: ...e 200MΩ Water resistance grade IPX5 Electric shock resistance first grade 2 Output loading index Heater AC220V 3KW x 1 Surf Water pump AC220V 2 HP x 3 water pump AC220V 1HP x 1 Air pump AC220V 0 7kw x 1 spa light AC12V 5W x 2 Ozone AC12V 15W x 1 water pump AC220v 0 25HP x 1 Radio 1 Frequency Range FM 87 0 108 0MHz 2 Maximum Output Power 10W 3 Speaker 8Ωdamp proof speaker ...

Page 11: ...11 ...

Page 12: ...12 ...

Page 13: ...OM ACN ACN ACN P2 P3L P3 NO COM NC NO COM PUMP3 PUMP2 P12 HEAT ACN ACN ACN P11 220VAC NC NO COM COM NO NC COM NO NC PUMP3L BLOWER CD SPK L SPK R LIGHT SENSOR LEAD IN WATER SWITCH WATER PIN POWER INPUT Creepage protector 100A switch PUMP3 Circulation CONNECTION FACE PUMP2 DVD ACN ACL HEAT PUMP11 MAIN BOARD ...

Reviews: