24
6.3 Cable Selection
Please select cable according to the following table.
Table 6-3 Specification of Cables for Electrical Connection
Inverter
Cable range
(
AWG
)
Cable recommended
(
AWG
)
DC side
AC side
DC side
AC side
PV+
、
PV-
U
、
V
、
W
PE
PV+
、
PV-
U
、
V
、
W
PE
JNP550L-V5
14-12
14-12
12
12
12
12
JNP750L-V5
14-12
14-12
12
12
12
12
JNP1K1L-V5
14-12
14-12
12
12
12
12
JNP1K5L-V5
14-12
14-12
12
12
12
12
JNP2K2L-SE-V5
14-12
14-12
12
12
12
12
6.4 AC Side Electrical Connection
Notice
!
It’s forbidden to connect several inverters in parallel to one pump.
Danger
!
Ensure that all cables have no charge before electrical operation!
Step1:
W ire connection of the connector:
Please connect the wire of AC connector according to the following
steps::