55
Positioning
Install this appliance at a location where the ambient temperature corresponds to the
climate class indicated on the rating plate of the appliance:
Climate class
Ambient Temperature
SN
+ 10ºC a + 32ºC
N
+ 16ºC a + 32ºC
ST
+ 16ºC a + 38ºC
T
+ 16ºC a + 43ºC
Location
The appliance should be installed well away from sources of heat such as radiators,
boilers, direct sunlight etc. Ensure that air can circulate freely around the back of the
cabinet. To ensure best performance, if the appliance is positioned below an
overhanging wall unit, the minimum distance between the top of the cabi-net and the
wall unit must be at least 50mm. Ideally, however, the appliance should not be
positioned below overhanging wall units. Accurate leveling is ensured by one or more
adjustable feet at the base of the cabinet.
This refrigerating appliance is not intended to be used as a built-in appliance.
Warning!
It must be possible to disconnect the appliance from the mains power
supply; the plug must therefore be easily accessible after installation.
Electrical connection
B
efore plugging in, ensure that the voltage and fre5uency shown on the rating plate
correspond to your domestic power supply. The appliance must be earthed. The power
supply cable plug is provided with a contact for this purpose. If the domestic power
supply socket is not earthed, connect the appliance to a separate earth in compliance
with current regulations, consulting a qualified electrician.
The manufacturer declines all responsibility if the above safety precautions are not
observed. This appliance complies with the E.E.C Directives.