background image

Oxford

®

Weigh Scale

7

English

Key functions

ON / OFF / ZERO / TARE

•  Press to switch on.
•  Press and hold for 3 seconds to switch off.
•  Press to return to zero which is at condition of ± 2% of full capacity.
•  Press to tare the weight.

The TARE function can be used to subtract any additional weight, i.e. a patient’s clothing or a sling to 

calculate a net value.
To use this function, simply weigh the additional items using the scale, press the ‘

ON/OFF/ZERO/

TARE’

 key so that the display reverts to zero.

You can now lift and weigh the patient as usual (including the additional items). The LCD display will 

now show a net value that excludes the weight of the additional items.

HOLD

•  When the HOLD function is enabled, the scale will sample 5 to 10 sets of readings and analyse the 

discrepancy. 

•  Press to store the weight value.
•  To disable the hold function, press the 

‘HOLD’

 key again.

Feature settings

Auto-off time adjustment:

This feature adjusts auto-off period following non-operation. When the selected time period has 

elapsed, the device will shut off automatically to save battery life.

Pre-set options:

 120 sec / 180 sec / 240 sec / 300 sec / Off.

Buzzer adjustment:

This function enables the user to turn the audible buzzer 

ON

 or 

OFF

 according to preference.

Zero

Hold

Summary of Contents for Oxford Classic

Page 1: ...User Instruction Manual Oxford Classic Digital Weigh Scale To avoid injury read user manual prior to use For alternative languages contact your authorised service provider ...

Page 2: ...ntroduction About Your Scale 3 2 Assembly and Commissioning Instructions 4 3 Safety Precautions 5 4 Operating Instructions 6 5 Battery Replacement 8 6 Maintenance Schedule and Error Identification 9 7 Technical Specifications 10 8 Warranty 12 ...

Page 3: ...aximum Safe Working Load The maximum safe working load of the Oxford Classic Digital Weigh scale is 300kg WARNING The maximum safe working load for the lift which the scale is fitted to should never be exceeded Recycling This product is not to be treated as regular household waste but should be handed into an electrical electronic equipment recycling centre You can obtain further details from your...

Page 4: ...de STEP 3 Press the ZERO key to enter AOFF mode STEP 4 Press the HOLD key to select 180 S indicating that the AUTO OFF time is 180 seconds STEP 5 Press the ZERO key to select and return to AOFF mode and press HOLD to enter to BEEP setup mode STEP 6 Press the ZERO key to enter BEEP setup mode and press HOLD again to select between ON and OFF STEP 7 Press the ZERO key to decide and return to BEEP se...

Page 5: ...device due to a risk of falling Following assembly to an Oxford patient lift the scale must not be rotated horizontally Rotation is only permitted in connection with 360 swivel bearings installed on the lift The device must not be modified from its standard configuration Unapproved modifications may result in injury and or death to the patient and or carer and will render all liability and warrant...

Page 6: ...operating instructions Always ensure the display shows Zero before use If it does not then please press the ZERO key The weigh scale is designed to detect when a stable weight is achieved your reading should be taken at this point CAUTION A tilt angle in excess of 3 will result in a false or inaccurate reading Panel indication Hold indicator Net weight Gross weight Kg unit Max 300kg Min 2kg e 0 1k...

Page 7: ...tient as usual including the additional items The LCD display will now show a net value that excludes the weight of the additional items HOLD When the HOLD function is enabled the scale will sample 5 to 10 sets of readings and analyse the discrepancy Press to store the weight value To disable the hold function press the HOLD key again Feature settings Auto off time adjustment This feature adjusts ...

Page 8: ...of this range the scale s battery life will be adversely effected When buying new batteries select batteries low in harmful substances and no mercury Hg Cadmium Cd or Lead Pb Instructions for replacing the battery Your scale uses 6 x AAA size alkaline batteries Please follow the instructions below for replacement 1 Locate the battery cover at the rear of scale 2 Remove the battery cover by sliding...

Page 9: ...ow battery indication This warning indicates that the voltage of the batteries is too low to operate Please replace the bateries Zero high The loading has exceeded the upper limit of the scale Please reduce the loading Zero low The loading has not achieved the lower limit of the scale Please increase the loading Over load or counting error The upper load limit of the scale has been exceeded Please...

Page 10: ... kg unit is approved by OIML International Organization of Legal Metrology Capacity Maximum safe working load 300kg Division 0 1kg Accuracy 0 15kg OIML Class III Display Options 1 0 inch 5 and 1 2 digits Weight Unit kg Dimensions 120 x 70 x 160mm Power Supply 1 5V AAA x 6 batteries Operating Temp 0 40 ...

Page 11: ...ent as per EN 60601 1 Class 2 equipment The disposal of batteries should not be mixed with general household waste Batteries should be disposed of in accordance with local or national regulations The disposal of electronics should not be mixed with general household waste For indoor use ATTENTION consult accompanying documents Refer to the user instructions before use WEEE Producers registration n...

Page 12: ...er so they can be contacted should any problem arise If you are in any doubt as to where your lift was purchased Joerns Healthcare can trace the supplier if you quote the serial number of the lift All warranty claims are subject to the correct use and maintenance in accordance with the user instruction manual provided with each lift Damage caused by use in unsuitable environmental conditions or fa...

Page 13: ...THIS PAGE IS INTENTIONALLY BLANK ...

Page 14: ...THIS PAGE IS INTENTIONALLY BLANK ...

Page 15: ...THIS PAGE IS INTENTIONALLY BLANK ...

Page 16: ...akes Broughton Business Park Worcester Road Drakes Broughton Pershore Worcestershire WR10 2AG United Kingdom T 0844 811 1156 F 0844 811 1157 www joerns co uk email info joerns co uk 2020 Joerns Healthcare 6110155 Rev C DCO20 0061 ...

Reviews: