vision
Snack Plus/Easy Combo
//
Vending
MNP86V03GBV00
Date: 2010/06/14 Rev. 0
PAGE 12 OF 62
The cooling unit consists of a compressor and a condenser located in the lower part of
the cabinet, as well as an evaporator located inside the product hold and an axial flow
fan that cools the condenser and the compressor motor. The cooling gas used is the gas
indicated on the machine compressor. The turbine is a fan with two runners located
inside the product hold which is permanently in operation.
A.
Compressor
B.
Condenser
C.
Fan
D.
Evaporator
E.
Turbine
Fig. 15
The machine carries out defrosting cycles to prevent ice from building up in the
evaporator of the cooling unit, which would have adverse effects on the unit’s
performance. The defrosting cycle consists of turning the cooling unit off long enough for
the ice build-up on the evaporator to disappear. A total of 3 defrosting cycles are carried
out a day at approximately 8-hour intervals. The unit is further defrosted three hours after
the machine has been restocked with product; in this case the internal temperature will
not be shown on the display until one hour after the defrosting cycle began.
There is a slotted area to permit air circulation through the inside area where the
compressor and condenser are located. This area is located at the front of the machine
cabinet.
The following conditions should be met for proper cooling system operation:
1º The slots should be kept free of dust and you should check regularly that they are not
obstructed with bags, papers, etc.
2º At the back of the cabinet there is a window that provides access to the cooling unit.
You should always keep the cooling unit clean to ensure a long service life.
The temperature is programmable between 4 °C and 12 °C with zone division.
Note:
For safety reasons, every time the unit is stopped and started, the
process is detained during a 4-minute interval.