A
B
Checkout and maintenance
1-6
F/P 36 TOGGLE ANGLES OF LEFT AND RIGHT WEIGHTS.
Begin procedure by mounting a tire and wheel assembly. Enter all wheel parameters and spin the tire and
wheel assembly. After
F/p36
is activated, machine displays
“pOs” “ANg”
first. Once the shaft moves,
machine displays encoder position in integer form (from 0 to 511) in left window and angle in floating form
(from 0.00 to 359) in right window. meanwhile, machine lights on the position bars to indicate the left weight
position. So working with number and position LEDs, it is very easy to find the left weight’s position value and
angle value. This function is very useful to check the position accuracy. Press the
<sTOp>
key to exit this
function.
F/P 43 RESETTING THE COUNTERS
The counter can be reset using this code:
Press and release the
1.
<F/p>
key, turn the shaft until the display reads “
F/p
”
“43”
is displayed and press
enter.
The balancer will display
2.
“Ctr” “rst”
.
The display shows the total number of spins since last reset. Press the STOP key while this number is
3.
displayed.
The total number of spins since the last reset has been reset to zero.
4.
The display changes to
5.
“rE-” “set”
for one second.
F/P 44 READ OR RESET PRODUCTIVITY OF USER
This displays or resets the total number of spins for either operator A,B,C or D depending what is chosen on
the main display.
Choose the operator that you would like to read or reset from the main PCB by pressing the operator
1.
mode key (A,B,C or D).
Press and release the
2.
<F/p>
key, turn the shaft until the display reads “
F/p
”
“44”
is displayed and press
<enter>
. The balancer will display
“A” “Ctr”
or
“B” “Ctr”
or
“C” “Ctr”
or
“D” “Ctr”
.
The next display shows the total number of spins for the operator chosen. Press the
3.
<sTOp>
key while
this number is displayed.
The total number of spins for that operator is now reset to zero.
4.
The display changes to
5.
“rst” “A”
or
“rst” “b”
for 1 second.
F/P 50 READ OUTPUT VOLTAGE OF THE DISTANCE POTENTIOMETER OF SAPE
Slide the SAPE in the home position.
1.
Press and release the
2.
<F/p>
key, turn the shaft until the display reads “
F/p
” “50” is displayed and press
enter.
Displays “3.10” “0.02” “3.10” With the Distance guage in the home position the voltage in the right hand
3.
display should read 3.10vDC ± 0.02. If the voltage setting is not within the tolerance the balancer will not
function correctly.
F/P 51 READ OUTPUT VOLTAGE OF THE DIAMETER
POTENTIOMETER OF SAPE
move the SAPE in the losest position.
1.
Press and release the
2.
<F/p>
key, turn the shaft until the display reads
“
F/p
” “51” and press enter.
Displays “3.10” “0.05” “3.10”. The voltage should read 3.10vDC ± 0.05
3.
(point A) when the SAPE is on the vibratory tube or 2.85vDC ± 0.05
(point B) when placed on the bell housing.
Summary of Contents for EEWB304B