Chapter 2 Diagonostic Codes
2-25
500
BL_BAL_ERROR_NoConverge
501
BL_BAL_ERROR_ResultInvalid
502
BL_BAL_ERROR_ToomuchLoops
510
BL_BAL_ERROR_NoCaluser
511
BL_BAL_ERROR_FailCaluser
512
BL_BAL_ERROR_SideCaluser
530
Distance of the virtual left plane from the reference plane out of range
560
c1 value too low, if a user calibration tool assumed
561
c2 value too low, if a user calibration tool assumed
565
c1 value too low, if a 100g weight and calibration rotor assumed
566
c2 value too low, if a 100g weight and calibration rotor assumed
570
c1 value too high, if a calibration rotor only assumed
571
c2 value too high, if a calibration rotor only assumed
580
-30°C
Temperature below -30°C or hardware fault.
581
100°C
Temperature above 100°C or hardware fault.
585
0.23 v
Temperature Input near to ground voltage.
586
4.05 v
Temperature Input near to reference voltage.
601
Internal error : To many event sinks
602
Internal error : Cannot register event sink
603
Internal error : Invalid event level
701
ERROR_IEmS_INv_PARAm
702
Incremental encoder not initialised.
- software is not able to detect the reference mark.
703
Incremental encoder : Counter - reference mark mismatch
705
2.50 v
Opto electronic, No voltage on shunt resistor
706
4.30 v
Opto electronic, vCC on shunt resistor
707
16 mA
Opto electronic, Current through LED below limit
708
20 mA
Opto electronic, Current through LED above limit
710
Hand-spin with electromagnetic released brake
- main shaft rotates backwards
800
170 V
Line voltage below limit
801
265 V
Line voltage above limit
804
275 V
Line voltage much too high
810
5.10 v
vCC below limit
811
5.35 v
vCC above limit
820
5.00 v
Keyboard/display voltage below limit
821
5.35 v
Keyboard/display voltage above limit
830
4.50 v
External voltage (pedal) below limit, see keyboard module
831
External voltage (pedal) above limit, see keyboard module