Checkout and maintenance
1-3
FUNCTIONs OF sNApON / JBC VpI BALANCERs
All the service codes are entered using
F/p
codes. The procedure for activating an
F/p
code is described
below.
Press and release the <
1.
F/p
> key, the left window displays letter “
F/p
” and right window displays current
F/p
code number.
Press and release the
2.
<F/p>
key, rotate the shaft to increase or decrease the number in the RH display
until the desired code number is reached.
In general, the
3.
F/p
code will display some brief information to the operator for 1 or 2 seconds, and the
machine enters the corresponding function.
sERVICE CODEs
The JBC balancer requires that the F button be pressed while the Snapon balancer uses the P button.
1
Toggle switch between fine and normal balancing mode.
2
Toggle switch between inch and millimeter display of width.
3
Toggle switch between gram and ounce display.
4
Calibration with adapter or disable adapter compensation.
7
Toggle switch of millimeter and inch for diameter measurement.
12
Read counters
14
Calibration by user
18
Enter ALu-S 2 plane mode (press the balancing mode key to exit back to the dynamic mode)
19
Enter ALu-S 1 plane mode (press the balancing mode key to exit back to the dynamic mode)
21
Check revision of balancing kernel software.
22
Power clamp lock. (JBC 3 power clamp model only)
28
Check last 10 kernel error messages & Clean all recorded error codes.
36
Toggle reading the positions and angles of left and right weights.
43
Read or reset re-setable counter.
44
Read or reset productivity of user. Display counter number of default user only.
Read output voltage of potentiometer of distance measurement of SAP
.
51
Read output voltage of potentiometer of the diameter measurement of the SAPE.
52
Read output voltage of potentiometer of the width measurement of the SAPE.
53
Display test
55
Check AC and DC voltages
59
Read resident imbalances of shaft in fine mode. (The fine mode LED indicator is
automatically turned on and off if the machine is in the regular accuracy mode).
60
Read shaft speed RPm.
63
Continuous spin.
64
Read outputs of transducers.
79
Calibration of the width SAPE.
80
Calibration of SAPE
83
manufacture calibration (Pruefrotor required).
84
Empty Calibration of the bare shaft.
88
Top Dead Center calibration (TDC)
90
Enter match balancing mode.
91
Optimization balancing mode.
92
Split weight mode.
94
Spoke mode.
95
Clean and reset EEPROm 1 & 2.
97
Sticky at Top.
Summary of Contents for EEWB304B
Page 1: ...WHEEL BALANCER Service Manual EEWB502B C EEWB503B EEWB304B ...
Page 56: ......