background image

  

5.

 If the pumped fluid is hazardous or toxic, appropriate precautions 

must be taken to ensure that any seal leakage is adequately
contained. Further information on sealing hazardous or toxic fluids
should be obtained from John Crane prior to seal installation. 

  

6.

 Fluorocarbon components should never be burned or incinerated 

as the fumes and residues are highly toxic. If fluorocarbons are
accidentally heated above 400˚C/750˚F, they can decompose.
Protective gloves should be worn as hydrofluoric acid may be present.

  

7.

 PTFE components should never be burned or incinerated as the

fumes are highly toxic. 

These instructions are for the installation and operation of
a seal as used in rotating equipment and will help to avoid
danger and increase reliability. The information required
may change with other types of equipment or installation
arrangements. These instructions must be read in
conjunction with the instruction manuals for both the 
pump and any ancillary equipment.

If the seal is to be used for an application other than that originally
intended or outside the recommended performance limits, John Crane
must be contacted before its installation and use.

Any warranty may be affected by improper handling, installation, or use
of this seal. Contact John Crane for information as to exclusive product
warranty and limitations of liability. 

If questions or problems arise, contact your local John Crane representative
or the original equipment manufacturer, as appropriate.

John Crane mechanical seals are precision products and
must be handled appropriately. Take particular care to
avoid damage to lapped sealing faces and to flexible
sealing rings. Do not excessively compress the seal
before or during installation.

Safety Instructions

  

1.

 The following designations are used in the installation instructions to

highlight instructions of particular importance.

      

NOTE: 

        

Refers to special information on how to install or
operate the seal most efficiently.

                           

Refers to special information or instructions directed
towards the prevention of damage to the seal or its
surroundings. 

                           

Refers to mandatory instructions designed to
prevent personal injury or extensive damage to the
seal or its surroundings. 

  

2.

 Installation, removal and maintenance of the seal must be carried out

only by qualified personnel who have read and understood these
installation instructions.

  

3.

 The seal is designed exclusively for sealing rotating shafts. The

manufacturer cannot be held liable for use of the seal for purposes
other than this.

  

4.

 The seal must only be used in technically perfect condition and

must be operated within the recommended performance limits in
accordance with its designated use set out in these installation
instructions.

Dry-running - often indicated by a squealing noise from 
the seal area - will cause overheating and scoring or other
damage to the sealing surfaces, resulting in excessive
leakage or a much shortened seal life.

Before start-up, ensure that all personnel and
assembly equipment have been moved to a safe 
distance so there is no contact with rotating parts
on the pump, seal, coupling, or motor.

WARNING:

Seal installation should be handled only by qualified
personnel. If questions arise, contact the local 
John Crane representative. Improper use and/or
installation of this product could result in injury to
the person and/or harmful emissions to 
the environment, and may affect any warranty 
on the product. Please contact John Crane for
information as to exclusive product warranty 
and limitations of liability.

Before Starting the Equipment

  

1.

 Check the pump at the coupling for proper alignment of the driver 

or motor.

  

2.

 Ensure that the gland plate nuts/bolts are securely tightened

according to the pump manual instructions, and that all screws are
securely fastened.

  

3.

 Complete the assembly of the pump, and turn the shaft (by hand if

possible) to ensure free rotation.

  

4.

 Consult all available equipment operating instructions to check for

correctness of all piping and connections, particularly regarding seal
recirculation/flush, heating or cooling requirements, and services
external to the seal.

                               This mechanical seal is designed to operate in a liquid

so the heat energy it creates is adequately removed.
Therefore, the following check should be carried out
not only after seal installation, but also after any 
period of equipment inactivity.

  

5.

 Check that the seal chamber fluid lines are open and free of any

obstruction, and ensure that the seal chamber is properly vented  
and filled with liquid - refer to the pump instruction manual.

ATTENTION

ATTENTION

ATTENTION

!

ATTENTION

ATTENTION

!

Foreword

These instructions are provided to familiarize the user with the seal
and its designated use. The instructions must be read and applied
whenever work is done on the seal, and must be kept available for
future reference.

TYPE 5625/5625P

DUAL METAL BELLOWS CARTRIDGE SEAL 

Installation, Operation & Maintenance Instructions

PAGE

1

Summary of Contents for 5625

Page 1: ... The seal is designed exclusively for sealing rotating shafts The manufacturer cannot be held liable for use of the seal for purposes other than this 4 The seal must only be used in technically perfect condition and must be operated within the recommended performance limits in accordance with its designated use set out in these installation instructions Dry running often indicated by a squealing n...

Page 2: ...VE 0 040 LG X 20 CHAM 63 0D 0 000 0 002 0 040 20 MOVE SHAFT IN AXIAL DIRECTION BY HAND NOTE MEASUREMENT ON DIAL INDICATOR MOUNT DIAL INDICATOR ON SHAFT TURN SHAFT BY HAND AND NOTE MEASUREMENT ON DIAL INDICATOR MOUNT DIAL INDICATOR ON SHAFT TURN SHAFT BY HAND AND NOTE MEASUREMENT ON DIAL INDICATOR MOUNT DIAL INDICATOR ON SEAL CHAMBER FACE Inboard Side Outboard Side Part Name 1 Mating Ring 7 Collar ...

Page 3: ...til seal faces touch 11 Install lubricated O ring into ID groove of sleeve adapter 12 Slide sleeve adapter over sleeve aligning pins of adapter with pins of sleeve Push down to engage drive flats until adapter stops at step of sleeve 13 Carefully slide snap ring over the end of sleeve Using assembly tool push the snap ring in place inside the sleeve adapter until it snaps in Type 5625 Dual Metal B...

Page 4: ...1 939 2 875 3 023 5 375 3 851 1 446 2 062 0 625 2 125 1 914 1 789 0 562 4 062 3 268 1 750 2 420 3 500 3 925 6 500 3 995 1 487 2 125 0 656 2 187 1 995 1 870 0 687 5 093 3 885 1 875 2 562 3 625 3 734 6 500 3 995 1 487 2 125 0 656 2 187 1 995 1 870 0 687 5 093 4 006 2 125 2 798 3 875 4 250 7 156 4 355 1 570 2 282 0 749 2 407 2 198 2 073 0 687 5 687 4 264 2 500 3 312 4 750 4 875 8 000 4 545 1 697 2 40...

Page 5: ...be carried out by qualified personnel It is the responsibility of the equipment user to ensure that any parts being sent to a third party have appropriate safe handling instructions externally attached to the package Quality Assurance This seal has been assembled in accordance with John Crane Quality Assurance Standards and with proper maintenance and use will give safe and reliable operation to t...

Page 6: ...on Carbide optional Nickel Binder Tungsten Carbide optional Mating Ring Silicon Carbide Nickel Binder Tungsten Carbide optional Cartridge Hardware 316 Stainless Steel Secondary Seal Fluoroelastomer Operating Limits Pressure Operating Up to 300 psig 21 barg Static Up to 450 psig 31 barg Inboard seal ID Reverse Up to 150 psig 10 barg Temperature 20 F to 400 F 29 C to 204 C Speed Up to 5000 fpm 25 mp...

Page 7: ...TYPE 5625 5625P DUAL METAL BELLOWS CARTRIDGE SEAL Installation Operation Maintenance Instructions PAGE 7 ...

Page 8: ...E products must not be incinerated ISO 9001 and ISO14001 Certified details available on request 2015 John Crane Revised 10 15 www johncrane com IOM 5625 5625P NorthAmerica United States of America Tel 1 847 967 2400 Fax 1 847 967 3915 Europe United Kingdom Tel 44 1753 224000 Fax 44 1753 224224 Latin America Brazil Tel 55 11 3371 2500 Fax 55 11 3371 2599 Middle East Africa United Arab Emirates Tel ...

Reviews: