background image

FLX43P

15 x 1/2"

FLX34P

10 x 1/2"

FLX35P

15 x 3/8"

FLX15P

15 x 1/2"

FLX16P

15 x 3/4"

FLX22P

22 x 3/4"

FLX18P

15 x 1/2"

FLX20P

15 x 3/4"

FLX19P

22 x 3/4"

FLX23 

Full Bore

22 x 3/4"

FLX40

15 x 1/2"

FLX42

15 x 3/4"

FLX41

22 x 3/4"

Not suitable for central heating systems.

Hot and Cold water only, 65°C max. 

500mm long

300mm long

P

ART

N

O

.

S

IZE MM

FLX33P

15 x 10

FLX17P

15 x 15

FLX26P

22 x 22

FLX21P

15 x 15

FLX27P

22 x 22

FLX47

15 x 15

300mm long

500mm long

BRAIDED FLEXI HOSES

P

ART

N

O

.

S

IZE

MM X BSP

BRASS VALVE
FLX24P

15 x 1/2”

FLX25P 

Full Bore

22 x 3/4”

FLX31P

15 x 1/2”

FLX38P

15 x 3/4”

FLX32P 

Full Bore

22 x 3/4”

PLASTIC VALVE
FLX37P

15 x 1/2”

FLX39P 

22 x 3/4”

PLASTIC VALVE WITH HANDLE
FLX37-H

15 x 1/2”

FLX39-H

22 x 3/4”

300mm long

500mm long

BRASS FITTINGS

P

ART

N

O

.

S

IZE

MM X BSP

Converts Speedfit to male thread.

P

ART

N

O

.

S

IZE

MM X BSPT

MW051504N

15 x 1/2” 

MW052206N

22 x 3/4”

MW052818N

28 x 1” BSP 

Suitable for central heating systems.

Manufactured in DZR Brass.

P

ART

N

O

.

S

IZE

MM X BSPT

MW011504N BRASS

15 x 1/2” 

MW012206N BRASS

22 x 3/4” 

MW012808N

28 x 1”

Suitable for central heating systems. 

Manufactured in DZR Brass.

P

ART

N

O

.

S

IZE

MM X BSP

22CFA

22 x 1  

Suitable for central heating systems.

Manufactured in DZR Brass.

P

ART

N

O

.

S

IZE

MM X BSP

22CMA

22 x 1  

Suitable for central heating systems.

Manufactured in DZR Brass.

SPEEDFIT X UNION NUT 

SPEEDFIT X SPEEDFIT

SPEEDFIT X UNION NUT WITH SERVICE VALVE

BRASS MALE COUPLER

BRASS BACK PLATE ELBOW

BRASS MALE STEM ADAPTOR

BRASS MALE CYLINDER ADAPTOR

BRASS FEMALE CYLINDER ADAPTOR

11

12

150mm long

1000mm long

P

ART

N

O

.

S

IZE

MM X MALE

FLX48

12 x M10

FLX28

15 x M10

FLX29

15 x M12

FOR MONOBLOC MIXERS

P

ART

N

O

.

S

IZE

MM X BSP

P

ART

N

O

.

S

IZE

MM X BSP

FLX36P

15 x 1/2”

ELBOW PATTERN

300mm long

300mm long

300mm long

500mm long

P

ART

N

O

.

S

IZE

MM X BSP

FLX49

15 x 3/8”

SPEEDFIT X MALE THREAD

300mm long

P

ART

N

O

.

S

IZE MM

SPEEDFIT X UNION NUT 

SPEEDFIT X PLAIN STEM

200mm long

SPEEDFIT X SPEEDFIT WITH SERVICE VALVE

BRASS VALVE
FLX44P

15 x 15 

FLX45P

15 x 15

P

ART

N

O

.

S

IZE

MM X MALE

FOR MONOBLOC MIXERS

P

ART

N

O

.

S

IZE

MM X BSP

SPEEDFIT X UNION NUT WITH SERVICE VALVE

P

ART

N

O

.

P

IPE

S

TEM

WFLX51

15 

15

IDENTITY DISCS

P

ART

N

O

.

P

ACK

Q

TY

WHITE PVC FLEXI HOSES

WFLX15

15 x 1/2”

WFLX16

15 x 3/4”

WFLX22

22 x 3/4”

WFLX18

15 x 1/2”

WFLX20

15 x 3/4”

WFLX19

22 x 3/4”

P

ART

N

O

.

S

IZE

MM X BSP

300mm long

500mm long

P

ART

N

O

.

S

IZE MM

WFLX17

15 x 15

SPEEDFIT X SPEEDFIT

300mm long

WFLX36

15 x 1/2”

ELBOW PATTERN

300mm long

P

ART

N

O

.

S

IZE

MM X BSP

P

ART

N

O

.

S

IZE

MM X BSP

10MC (1/2) BRASS

10 x 1/2”

15MC (1/2) BRASS

15 x 1/2”

22MC (3/4) BRASS

22 x 3/4”

MW012818N

28 x 1”

PLASTIC VALVE WITH HANDLE
WFLX37-H

15 x 1/2”

WFLX39-H

22 x 3/4”

300mm long

WFLX28

15 x M10

WFLX29

15 x M12

300mm long

FLX - RED

10

FLX - BLU

10

1000mm long

SPEEDFIT X PLAIN STEM

300mm long

P

ART

N

O

.

P

IPE

S

TEM

FLX53

15 

15

Not suitable for central heating systems.

Hot and Cold water only, 65°C max. 

For handles on service valves.

P

ART

N

O

.

S

IZE

MM X BSP

MW501514N

15 x 1/2” 

MW502216N

22 x 3/4” 

Suitable for central heating systems.

Manufactured in DZR Brass.

Converts Speedfit to female thread.

BRASS FEMALE STEM ADAPTOR

15WB

15 x 1/2"

22WB

22 x 3/4"

Manufactured in DZR Brass.

Suitable for central heating systems.

SHORT VERSION

15WB2

15 x 1/2"

Manufactured in Brass.

Suitable for central heating systems.

Summary of Contents for Speedfit

Page 1: ...rposes only Subject to our Terms and Conditions of Sale available on request Z2105 217 10 07 No s 95 3177 BS7291 KM39767 AVAILABLE FROM THE PUSH FIT SOLUTION FOR PLUMBING HEATING SYSTEMS UK PRODUCT RA...

Page 2: ...ducts A reputation built on producing consistently high quality products with an ongoing commitment to value engineering and product development 01 02 Technical Support Our national team of Technical...

Page 3: ...s application Speedfit fittings suitable for central heating systems can withstand temperatures up to 114 C intermittently for short periods Speedfit fittings shown as not suitable for central heating...

Page 4: ...ead The O ring on the Superseal Pipe Insert provides a secondary seal against the bore of the fitting A good connection has been made Gap between Cap and Flange Pipe mark indicates full insertion Twis...

Page 5: ...e connectors are useful when replacing existing brassware or in other confined spaces Coupling up to a supply is easy The pipe is simply pushed home into the Speedfit connection and is instantly secur...

Page 6: ...28 x 22 PEMSTC1514 15mm x 1 2 BSP PEMSTC1516 15mm x 3 4 BSP PEMSTC2216 22mm x 3 4 BSP PEMBTC1514 15mm x 1 2 BSP PART NO SIZE MM PSE4610W 10 PSE4615W 15 PSE4622W 22 Suitable for central heating systems...

Page 7: ...50mm long 1000mm long PART NO SIZE MM X MALE FLX48 12 x M10 FLX28 15 x M10 FLX29 15 x M12 FOR MONOBLOC MIXERS PART NO SIZE MM X BSP PART NO SIZE MM X BSP FLX36P 15 x 1 2 ELBOW PATTERN 300mm long 300mm...

Page 8: ...15BPEX 120C 15mm x 120m 15BPEX 150C 15mm x 150m 22BPEX 25C 22mm x 25m 22BPEX 50C 22mm x 50m Suitable for central heating systems Coils The pipe has an inner barrier to stop the ingress of atmosphere...

Page 9: ...Copper pipe PE copper coupler MDPE pipe with Pipe Insert Collet clip Speedfit Pipe Speedfit pipe should never be connected directly to a boiler Although most modern boilers have a high limit thermost...

Page 10: ...M M M M M M P P Plastic M Metal NB All Waste Pipes are plastic 1 Supplementary bonding is carried out to the earth terminal of protective conductors of class I and class II equipment within the bathro...

Page 11: ...rs does not affect the fire resistant properties of the structure Speedfit pipework can be easily cabled through studwork and within wall systems as well as behind dot and dab plasterboard installatio...

Page 12: ...ntrolled by one or more thermostats which signal the Pump Pack when heat is required 21 22 RADIATOR SYSTEM AND HEAT GRADIENT UNDERFLOOR HEATING SYSTEM An Underfloor Heating System heats mainly by radi...

Page 13: ...ntralised control of the set back functions for the whole manifold via a digital programmer The timer acts as a timed switch to alternate between daytime and Set Back time PART DESCRIPTION PACK NO QTY...

Page 14: ...on of the outside walls and windows will determine the pattern of the pipe layout The counterflow pattern is recommended although other options are shown below Single Serpentine Double Serpentine Trip...

Page 15: ...nst the face of fitting With the collet held in this position the pipe can be withdrawn We recommend the replacement of the O ring and collet before making a new connection Remove collet cover pull ou...

Page 16: ...ulose based paints paint thinners or strippers solder flux or acid based descalents or aggressive household cleaning products Exposure to sunlight Speedfit products when used indoors are not affected...

Reviews: