Thank you for purchasing this Balance wall light. Please read the instructions 

carefully before use to ensure safe and satisfactory operations of this product. 

Please keep this instruction for future reference.

 

 

Warnings! 

 

For your safety, this product must be installed in accordance with local Building 

Regulations. 

If in any doubt, or where required by the law, consult a competent person who is 

registered with an electrical self-certification scheme. Further information is 

available online or phone your Local Authority. 

To prevent electric shock, switch off the mains supply before installing or 

maintaining this product. Ensure other persons cannot restore the electricity supply 

without your knowledge.  

Always use the correct bulb type with the correct wattage as indicated in the 

specification table. This product is Class II =      and should be fitted to a lighting 

Supply protected by a 5 amp fuse or equivalent circuit breaker.

 

When changing the bulb, always switch off at the mains and allow the old bulb to 

cool down before handling. Dispose of used bulbs carefully. 

Caution! The bulb and surrounding parts can become hot during use. 

For indoor use only. 

 

Care instructions 

 

We recommend cleaning with a soft dry cloth. Do not use abrasive materials as 

these will damage the finish. 

Replace bulb from John Lewis or established brand of the same type and 

compatibility. 

 

Parts list 

 

Part List 

Qty 

 

Part List 

Qty 

 

Part List 

Qty 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Assembly 

Never install your appliance on a wet, freshly painted or plastered surface. Ensure 

the house electricity supply is switched off at the fuse box. If removing an existing 

fitting, note down all wiring connections. Check the fixings will not touch any 

existing wiring before drilling and attaching the light to the ceiling. 

Ensure you thread the ceiling wires through the black insulating tube fixed to the 

appliance. 

 

Step 1

 

 

Remove mounting bracket from fitting by removing 

the retaining screws and any washers, retain for later. 

Using the mounting bracket as a template, mark and 

then drill the fixing holes in the wall (ensure the screws 

are firmly fixed into a solid or other suitable mounting 

and not just the plasterboard.) Take care not to 

damage wiring. Attach mounting bracket to the 

mounting surface using suitable fixings. Do not attach 

fitting to mounting bracket at this stage. Make sure 

no wires are trapped in the process. 

   

 

Step 2 

Ensuring that the power has been isolated, connect 

the  electrical supply wires to the connector blocks 

corresponding terminals.  Make the electrical 

connection as follows: 

 

Connect the supply live (normally brown or red) to 

fitting live (marked “L”) on the terminal block housing. 

 

Connect the supply neutral (normally blue or black) 

to fitting neutral (marked  “N”) on the terminal block 

housing. 

NO EARTH

 must be connected to any part of this 

fitting. 

Please note

 that residential wiring can vary, if 

you are unsure about the correct polarity please 

consult a qualified electrician. Ensure electrical 

connections are tight and no loose strands of wire protrude from the terminal 

block then close connector block cover by snapping back together. 

 

Step 3 

 

Excess cable must be carefully located inside the 

ceiling cup or within the ceiling cavity itself. 

Carefully offer fitting over mounting bracket then 

secure in place with the screws and any washers 

removed earlier. 

Fit the bulb

:  type and wattage as indicated on the 

fitting.  

The wattage indicated must not be exceeded.

 

 

Fit the shades

 by placing the threaded hole in the shade over the lamp holder 

section and rotating into place. If cross-threading occurs undo and start again. 

Take care not to overtighten as this may cause damage to the fitting.  

Once installation is complete, the house electricity may be restored at the fuse 

box. 

 

 