6. Adjust water flow by lifting water valve upward and downward to fit different scrubbing require-
ments (Figure 13).
7. When stopping scrubbing, turn off the brush motor and squeegee motor switches as well as the
main power switch to lift the brush and squeegee assembly.
DURING OPERATION
WARNING: Do not pick up any inflammable materials or reactive metal in case of fire or explosion.
FOR SAFETY: Go slowly on inclines and slippery surfaces and wear non-slip shoes.
1. Overlap the two scrub paths for 5 centimeters.
2. Keep the machine running to avoid damages to the ground.
3. Clean up the scrubbing area in advance to avoid scuff marks, if any, wipe the squeegee blade
with a piece of rag to remove the debris on it.
4. Do not operate the machine on inclines exceeding 5% (3°).
5. Add a moderate quantity of defoamer to recovery tank to remove additional foam.
NOTE: Keep the foam away from sewage screen filter in the recovery tank in case of motor failure.
6. A dual cleaning method is recommended when scrubbing heavily dirty area. Do scrubbing with
the squeegee lifted, wait 3-5 minutes for the solution to soak before scrubbing again with
squeegee down.
7. Lift the squeegee and brush, turn off all the power switches and remove the key before
operators leave.