- 36 -
User Guide
JVC85BCT
PUSH, TOW AND TRANSPORT THE MACHINE
SPECIFICATIONS
FAULT CODES OF THE CHARGER
LED2 turns
GREEN and
blink
Battery voltage <22V
Charge the battery with 24V,
15-25Ah mode, then continue
normal charging with intelligent
charger.
Battery voltage cannot reach 22.4V
LED2 turns
RED
Battery voltage<12V
Battery terminals are not well
connected; battery connection
failure.
Note
1. Charger for liquid-adding batteries mustn't adapt to maintenance-
free batteries to avoid charger burning-out
2. Charger for maintenance-free batteries adapts to liquid-adding
batteries. But the battery cannot be fully charged
3. If battery voltage is lower than 22V, the intelligent charger won't
work
4. Voltage lower than 23V will activate an alarm to warn for timely
charge
5. Faults above are only practical for new batteries. In terms old
batteries, please replace or maintain them
6. In general, the operation interface will raise the alarm in the event of
insufficient voltage. In this case, please get the batteries charged time,
otherwise faults above will occur.
MACHINE DIMENSION & CAPACITY
Code
Fault
Solution
JVC85BCT
Length :
1380 mm / 54,3"
Height :
1020 mm / 40"
Width / Frame :
900 mm / 35,4"
Width / Squeegee assembly:
1100 mm / 43,3"
Brush diameter:
405 mm / 16"
Cleaning path:
800 mm / 31,5"
Solution tank capacity:
70 L
Recovery tank capacity:
75 L
Weight (battery not included):
156 kg
Weight (battery included):
242 kg