- 11 -
5.5.
Battery Installation (battery)
Two different types of battery may be installed:
Leak proof battery: the electrolyte level must be checked regularly. When necessary, please fill up with distilled water
until the plates are covered.
Gel battery: this type of battery is maintenance free. The type of battery used must correspond to machine’s technical
specifications. The use of heavier batteries could seriously jeopardise machine’s manoeuvrability and lead to motor
brush overheating. While the use of batteries with lower capacity and weight requires more frequent charge.
CAUTION
To protect and extend batteries life, the machine cannot be used continuously when the power is used up.
5.5.1.
Batteries - Preparation
DANGER
The operator must be provided with the necessary protection devices to limit the risk of accident when installing the
batteries or doing maintenance. Keep away from naked flames, sparks, smokes and avoid short-circuit.
The batteries are normally filled with acid and ready for use. If the batteries are dry, it should be proceeded before
mounting. Remove the cap and fill every element with specific sulphuric acid solution until the plates are entirely
covered.
Leave for 4 or 5 hours to allow the plates to absorb the electrolyte. Make sure the level of electrolyte is still above the
plates or fill up with sulphuric acid solution. Close the caps. Mount the batteries on the machine
Before using the machine for the first time, please charge the batteries, following instructions.
5.5.2.
Batteries - Installation and connection
DANGER
Check that all switches on the control panel are in the “O” (off) position.
a) Make sure to connect the terminal “+” with positive pole of the battery.
b) Follow the instructions given below or it may cause an explosion.
c) Make sure the two tanks are empty.
d) Lift the recovery tank and tilt it backwards by about 90
o
to uncover the batteries compartment.
e) Place the batteries into the compartment correctly.
IMPORTANT
Mount the batteries suitable for their weight and pay attention to the differences between positive and negative
poles.
a) Connect the battery cable based on the wiring diagram and tighten the terminals on the poles.
b) Place the water tank in to its working position and fasten it to the detergent tank.