8
DESCRIPTION
Unit
SGT 30
SGT 40
DATA NATURAL GAS G20 - 20 mbar:
Nominal load (gross)
kW
7,5
8,4
Nominal capacity
kW
6,5
7,6
Supply pressure
mbar
20
20
Burner pressure
mbar
12,5
12,5
Gas consumption
*
m
3
/h
0,8
0,9
Diameter main orifice
mm
2,30
2,40
Diameter pilot orifice
mm
2 x 0,27
2 x 0,27
Heating time
∆
T= 45 K
min.
56
63
GENERAL
Storage capacity
litres
110
145
Water connections
**
-
3/4"-14 NPT
3/4"-14 NPT
Gas connection
-
150 7/1 - Rp ½
150 7/1 - Rp ½
Drain valve
-
3/4"-14 NPT
3/4"-14 NPT
Anode
-
3/4"-14 NPT
3/4"-14 NPT
T&P-plug **
-
3/4"-14 NPT
3/4"-14 NPT
Maximum operation pressure
bar
8
8
Empty weight
kg
58
70
1.3.2 Technical description
Toestel categorie:
I
2L
*
Gas consumption at 1013,25 mbar and 15°C
** For a leak-proof sealed connection European coupling pieces can be used on the
NPT-connection nipples with a pipe thread of ISO 228/1- G 3/4 of