Summary of Contents for EB

Page 1: ...on of State Codes may create a hazard and may ruin the equipment In addition the National Manufactured Housing Construction and Safety Standards Act and its Regulations require the use of compo nents listed or certified by a nationally recognized testing laboratory in all manufactured homes built and sold subject to that act To avoid the possibility of electrical shock do not open electrical box p...

Page 2: ...EAKERS Your electric furnace is equipped with a unique safety feature circuit breakers These circuit breakers are located behind the door of the fur nace near the bottom of the furnace See Figure 1 If a component should fail inside the furnace the circuit breakers will prevent damage that can be caused by an electrical short If the breakers ever trip they can be reset by first turning off the powe...

Page 3: ...N Your furnace s best friend is your service technician If the unit gives any indication of improper operation call your authorized service tech nician If the service technician is allowed to perform the normal routine care of your furnace many times he can detect potential difficulties and make corrections before trouble develops Preventive maintenance of this type will allow you to operate this ...

Page 4: ...570930 BUM C 0112 4 Johnson Controls Unitary Products SECTION V REPAIR PARTS LIST 1 24 25 3 4 5 6 26 9 10 11 7 17 16 15 20 21 22 23 12 27 13 14 19 17 18 29 28 1 ...

Page 5: ...S1 02541238000 4 8Kw 9 6Kw S1 02541237000 S1 02541236000 18 Limit Switch S1 02541249000 Open 200 Close 60 S1 02541249000 Open 200 Close 60 S1 02541249000 Open 200 Close 60 19 Fusible Link S1 02435663000 S1 02435663000 S1 02435663000 20 Bracket Circuit Breaker 3500 128 3500 128 3500 128 21 Circuit Breaker 1 Req d S1 3500 377P A Circuit Breaker 2 Req d S1 3500 377P A S1 3500 377P A 22 Buss Bar See N...

Page 6: ...1240000 2 Ea 9 6Kw S1 02541236000 10 4Kw 11 2Kw S1 02541240000 S1 02541238000 18 Limit Switch S1 02541249000 Open 200 Close 60 S1 02541249000 Open 200 Close 60 S1 02541249000 Open 200 Close 60 19 Fusible Link S1 02435663000 S1 02435663000 S1 02435663000 20 Bracket Circuit Breaker 3500 128 3500 128 3500 128 21 Circuit Breaker 2 Req d See Note 2 S1 3500 377P A S1 3500 377P A S1 3500 377P A 22 Buss B...

Page 7: ...570930 BUM C 0112 Johnson Controls Unitary Products 7 NOTES ...

Page 8: ...and service instructions 10 Cleaning replacement of filters or any other routine maintenance as set out in the User s Information Maintenance and Service Manual 11 Replacement or cleaning of nozzles or orifices 12 Fuses either internal or external to the product 13 Excessive fuel or electricity consumption THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE IMPLIED ...