Installation Instructions

LC-203/BLC-203 and LC-204/BLC-204 

2

ISTISJCEBLC2034 0.0

LC-203/BLC-203/LC-204/BLC-204 Microwave frequency: 10.525GHz

4. CONNECTION AND SETUP

Dip 

LED

 --> off = LED off - on = LED on

*

Dip 

HIGH/LOW

 --> off = 7m - on = 15m range

Dip 

NORM/PULSE

 --> off = 1 pulse - on = 2 pulse

Dip 

AND/OR

-

AUTO

 --> off-off = AND; on-off = OR; on-on = auto OR

Trimmer 

RANGE

 = used only for microwave. 

NOTE:

 The 

RANGE

 

trimmer may need to be adjusted to the maximum position in order 
to achieve maximum area of coverage as indicated in Figure 3.

Technical Features

RANGE

15 m

HORIZONTAL COVERAGE

100°

LENSES

LODIFF

®

 Fresnel Lens

POLY IR

®

4 Material

LED

green, yellow, blue

ALARM DURATION

2 s

SELF-DIAGNOSTICS

-

LED WALK TEST

YES

MICROWAVE FREQUENCY

10.525 GHz

MAXIMUM RADIO-
FREQUENCY POWER

+14 dBm

SOLID STATE RELAY

YES

EOL RESISTANCE

YES

CREEP ZONE DEVICE

YES

CASE TAMPER

YES

BACK TAMPER

YES

ANTI-MASKING

LC-203/BLC-203

DOUBLE PULSE

YES

RFI PROTECTION

30 V/m

HEAT COMPENSATION

YES

FULLY DIGITAL

YES

JOINT

YES

POWER SUPPLY 

9-15 VDC / 56 mA

UL/ULC tested: 10.6-13 VDC / 56 mA

COVER MATERIAL

ABS

PET IMMUNITY

YES

OPERATING TEMPERATURE

-10°C to +40°C

UL/ULC tested: 0°C to 49°C

HUMIDITY

93% RH

DIMENSIONS

114 x 63 x 40 mm

Jumpers 

T

 - 

A

 - 

EOL

 open = NC contacts without resistors (not for UL/ULC applications)

Jumpers 

T

 - 

A

 - 

EOL

 closed = DEOL supervision with internal resistors

Power supply = 9-15 VDC / 56 mA. UL/ULC tested: 10.6-13 VDC / 56 mA. 

Note:

 For 

UL/ULC installations the detector shall be provided with minimum of 4 hours of standby 
power from either a listed compatible control unit or power supply. Use only resistive 
loads on the outputs.
MASK terminals = antimasking terminals present on LC-203/BLC-203 only

DEOL supervision

(internal resistors/closed jumpers)

LC-203/LC-204: 

DEOL supervision

(external resistors/

open jumpers)

NC (no EOL supervision/

open jumpers)

Not used on UL/ULC 

listed installations

101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146

fresnel technologies inc.

2003

SIDE VIEW:

2.1m

(6.8ft)

TOP VIEW:

10m

(33ft)

(50ft)

15m

FRONT VIEW:

(50ft)

15m

5m

(16ft)

jay

WP 0.9 GI 6 T1

PET IMMUNE ARRAY

(28.2ft)

8.6m

(15.7ft)

4.8m

(6.8ft)

2.1m

35.6mm

(1.4 in)

49.8 mm

(1.96 in)

12.5 mm

(0.49 in)

95°

5m

(16ft)

10m

(33ft)

(50ft)

15m

0

Figure 7

101W. MORNINGSIDE DR. FORT WORTH, TX 76110, U. S. A. (817) 926-7474, FAX:(817)926-7146

fresnel technologies inc.

2003

SIDE VIEW:

2.1m

(6.8ft)

TOP VIEW:

10m

(33ft)

(50ft)

15m

FRONT VIEW:

(50ft)

15m

5m

(16ft)

jay

WP 0.9 GI 6 T1

PET IMMUNE ARRAY

(28.2ft)

8.6m

(15.7ft)

4.8m

(6.8ft)

2.1m

35.6mm

(1.4 in)

49.8 mm

(1.96 in)

12.5 mm

(0.49 in)

95°

5m

(16ft)

10m

(33ft)

(50ft)

15m

0

Figure 7

*remote activation and deactivation of walk test LED for LC-203/BLC-203 only: 

connect a 39 ohm resistor in series with the positive power supply, 

connect the NC output command in parallel with the R (see figure). The command should have a time of 3 or 4 seconds. At each command you will be able to 
turn the led on and off. For each connected detector add an R in parallel to the first one, and connect the power supplies that are in common.

10m

(33ft)

5m

(16ft)

5m

(16ft)

10m

(33ft)

2.1m

(6.8ft)

2.1m

(6.8ft)

4.8m

(15.7ft)

8.6m

(28.2ft)

15m

(50ft)

SIDE VIEW:

0

Zx COM

+

TAMPER

EOL

A

T

EOL

ALARM

TAMPER

EOL

LC-203/LC-204

SUPPLY

+

5.6 kohm

5.6 kohm

All 3 jumpers open

Negative connected

tamper

Panel

Zx COM

+

TAMPER

EOL

A

T

EOL

ALARM

TAMPER

EOL

SUPPLY

+

All 3 jumpers open

Negative connected

tamper

Panel

Detector

Zx COM

+

EOL

A

T

EOL

ALARM

TAMPER

EOL

TAMPER

COM

R1

R2

NC / NO

TAMPER

SUPPLY

+

NC

C

All 3 jumpers closed

Zone ok = R1

Zone in alarm = R1 + R2

Tamper zone = open or short circuit

Negative connected

tamper

Panel

LC-203/LC-204: R1 = 5.6 kohm; R2 = 5.6 kohm

BLC-203/BLC-204: R1 = 5.0 kohm; R2 = 5.0 kohm

Output

3 or 4 s pulse

39 ohm

*

Detector

BLC-203/BLC-204: 

DEOL supervision

(external resistors/

open jumpers)

COM Zx

+

TAMPER

EOL

A

T

EOL

ALARM

TAMPER

EOL

BLC-203/BLC-204

SUPPLY

+

10 kohm

10 kohm

All 3 jumpers open

Negative connected

tamper

Panel

- Fig 3 -

SK

AT CZ EE FR

GB

GE