background image

M9000-310 and M9000-320 Series Weather Shield Enclosures Installation Instructions

2

Parts Included     

Table 1:  Parts Included in M9000-310 and M9000-320 Weather Shield Enclosure Kits

Quantity

Description

1

Enclosure Base and Seal Assembly

1

Cover and Gasket

4

Cover Screws

2

Mounting Brackets

8

No. 12-24 x 1/2 in. Hex-Head Screws with Nitrile Patch

1

Anti-Rotation Bracket

2

M3 x 8 mm Phillips Screws

2

M4 Washers

2

Strain Relief Conduit Fittings with 1/2 in. National Pipe Straight Mechanical (NPSM) Exit

1

1

Cap Plug

2

Threaded Hex Nuts

1

Appliance Cord - 6 Conductor, 18 AWG Wire Gauge, 43 in. (109 cm)

1

Shaft Extender with Set Screw (M9000-320 Kit Only)

1.

It is recommended that 1/2 in. liquid-tight conduit and 1/2 in. National Pipe Thread (NPT) liquid-tight fittings (purchased 
locally) be used to terminate the control wiring to the weather shield enclosure strain relief conduit fittings.

Mounting
Brackets

No. 12-24 x 1/2 in.
Hex-Head Screws
(Eight Locations)

Threaded
Hex Nuts

Enclosure Base and
Seal Assembly

Cover Screws

(Four Locations)

Cover and
Gasket

Strain Relief
Conduit Fittings
(Two Locations)

Anti-Rotation

Bracket

M3 x 8 mm
Phillips Screws and
M4 Washers (Two Locations)

F

IG

:p

rt

s_

in

cl

Figure 1: Parts Included in M9000-310 and M9000-320 Weather Shield Enclosure Kits (See Table 1)

Summary of Contents for M9000-320 Series

Page 1: ...nformation on the M9000 Series Electric Actuators and Valve Linkages used with the M9000 310 and M9000 320 Weather Shield Enclosures M9106 xGx 2 Series Electric Non Spring Return Actuators Installatio...

Page 2: ...Appliance Cord 6 Conductor 18 AWG Wire Gauge 43 in 109 cm 1 Shaft Extender with Set Screw M9000 320 Kit Only 1 It is recommended that 1 2 in liquid tight conduit and 1 2 in National Pipe Thread NPT li...

Page 3: ...ble 2 Weather Shield Enclosure Dimensions in mm Dimension Weather Shield Enclosure M9000 310 M9000 320 A 7 7 8 200 13 3 8 340 B 4 23 32 120 5 29 32 150 C 3 17 32 90 4 23 32 120 D 4 27 32 123 6 1 32 15...

Page 4: ...ted from the inside of the enclosure so that the nitrile patch seals the mounting hole in the base 6 Install the enclosure and mounting bracket assembly onto the damper shaft extension Orient the asse...

Page 5: ...re base using two M3 x 8 mm Phillips screws and M4 washers included with the kit Tighten the Phillips screws to a torque of 15 to 20 lb in 1 7 to 2 3 N m 4 Orient the two mounting brackets onto the pr...

Page 6: ...from Step 3 14 Center the shaft or shaft extension in the actuator hub For the M9220 reinstall the actuator gripper assembly and secure in place using the spring clip Secure the actuator coupler asse...

Page 7: ...116 M9124 and M9132 4 to 122 F 20 to 50 C M9220 40 to 131 F 40 to 55 C Weather Shield Enclosure Ambient Storage Temperature Limits 40 to 176 F 40 to 80 C Electrical Connections Strain Relief Conduit F...