background image

Published in U.S.A.

www.johnsoncontrols.com

M9000-310 and M9000-320 Series Weather Shield Enclosures Installation Instructions

7

Metasys® and Johnson Controls® are registered trademarks of Johnson Controls, Inc.

All other marks herein are the marks of their respective owners. © 2016 Johnson Controls, Inc.

Building Efficiency

507 E. Michigan Street, Milwaukee, WI  53202

Technical Specifications     

M9000-310 and M9000-320 Weather Shield Enclosures

Materials

Enclosure

Impact-Grade ABS Plastic

Enclosure Seal

Nitrile

Cover

Transparent Impact-Grade ABS Plastic with Ultraviolet Inhibitors

Cover Gasket

Neoprene

Weather Shield Rating

NEMA 3R, IP32

Actuator Ambient 
Operating 
Temperature Limits

M9106 and M9109
(M9000-310 Only)

-4 to 122°F (-20 to 50°C)

M9108, M9116, 
M9124, and M9132

-4 to 122°F (-20 to 50°C)

M9220

-40 to 131°F (-40 to 55°C)

Weather Shield Enclosure Ambient Storage 
Temperature Limits

-40 to 176°F (-40 to 80°C)

Electrical Connections

Strain Relief Conduit Fittings with 1/2 in. National Pipe Straight Mechanical 
(NPSM) Exit

Shipping Weight

M9000-310

2.0 lb (0.9 kg)

M9000-320

3.3 lb (1.5 kg)

The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these 
specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or 
misuse of its products.

European Single Point of Contact:

NA/SA Single Point of Contact:

APAC Single Point of Contact:

JOHNSON CONTROLS
WESTENDHOF 3
45143 ESSEN
GERMANY

JOHNSON CONTROLS
507 E MICHIGAN ST
MILWAUKEE WI 53202
USA

JOHNSON CONTROLS
C/O CONTROLS PRODUCT MANAGEMENT
NO. 22 BLOCK D NEW DISTRICT
WUXI JIANGSU PROVINCE 214142
CHINA

Summary of Contents for M9000-320 Series

Page 1: ...nformation on the M9000 Series Electric Actuators and Valve Linkages used with the M9000 310 and M9000 320 Weather Shield Enclosures M9106 xGx 2 Series Electric Non Spring Return Actuators Installatio...

Page 2: ...Appliance Cord 6 Conductor 18 AWG Wire Gauge 43 in 109 cm 1 Shaft Extender with Set Screw M9000 320 Kit Only 1 It is recommended that 1 2 in liquid tight conduit and 1 2 in National Pipe Thread NPT li...

Page 3: ...ble 2 Weather Shield Enclosure Dimensions in mm Dimension Weather Shield Enclosure M9000 310 M9000 320 A 7 7 8 200 13 3 8 340 B 4 23 32 120 5 29 32 150 C 3 17 32 90 4 23 32 120 D 4 27 32 123 6 1 32 15...

Page 4: ...ted from the inside of the enclosure so that the nitrile patch seals the mounting hole in the base 6 Install the enclosure and mounting bracket assembly onto the damper shaft extension Orient the asse...

Page 5: ...re base using two M3 x 8 mm Phillips screws and M4 washers included with the kit Tighten the Phillips screws to a torque of 15 to 20 lb in 1 7 to 2 3 N m 4 Orient the two mounting brackets onto the pr...

Page 6: ...from Step 3 14 Center the shaft or shaft extension in the actuator hub For the M9220 reinstall the actuator gripper assembly and secure in place using the spring clip Secure the actuator coupler asse...

Page 7: ...116 M9124 and M9132 4 to 122 F 20 to 50 C M9220 40 to 131 F 40 to 55 C Weather Shield Enclosure Ambient Storage Temperature Limits 40 to 176 F 40 to 80 C Electrical Connections Strain Relief Conduit F...

Reviews: