SAFETY  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Specific safety rules and precautions  . . . . . . . . . . . . . . . . . . . . . . . 1

EXAMINING THE FURNACE INSTALLATION . . . . . . . . . . . . . . . . . . 2
START-UP AND SHUTDOWN   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

How your gas furnace works  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Operating instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Turning off the appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

FURNACE MAINTENANCE - USER INFORMATION   . . . . . . . . . . . . 4

External air filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Cleaning your filter   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Blower care   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5
Motor lubrication   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5

SERVICE INFORMATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5

Troubleshooting problems  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5
Furnace control diagnostics  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5
Furnace maintenance - dealer/contractor   . . . . . . . . . . . . . . . . . . .  5
Replacement parts list  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5
Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5

Limited Warranty   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7

Contact information

• Go to website at www.york.com, then click on 

Contact Us

 and 

follow the instructions.

• Contact us by mail:

Johnson Controls Ducted Systems

Consumer Relations

5005 York Drive

Norman, OK 73069

Read all sections of this manual and keep the manual for
future reference.

 

SECTION I: SAFETY

This  is  a  safety  alert  symbol.  When  you  see  this  symbol  on
labels  or  in  manuals,  be  alert  to  the  potential  for  personal
injury.

Understand and pay particular attention to the signal words 

DANGER

,

WARNING

, or 

CAUTION

DANGER 

indicates  an 

imminently

  hazardous  situation,  which,  if  not

avoided, 

will result in death or serious injury

.

WARNING 

indicates  a 

potentially

  hazardous  situation,  which,  if  not

avoided, 

could result in death or serious injury

.

CAUTION 

indicates  a  potentially  hazardous  situation,  which,  if  not

avoided 

may  result  in  minor  or  moderate  injury.

  It  is  also  used  to

alert against unsafe practices and hazards involving only property dam-
age.

Specific safety rules and precautions

1. The furnace area must be kept clear and free of combustible mate-

rials, gasoline, and other flammable vapors and liquids.

2. Insulating materials may be combustible. The furnace must be kept

free  and  clear  of  insulating  materials.  The  furnace  area  must  be
examined  when  installed  in  an  attic  or  other  insulated  space,  or
when insulation is added, to be sure that the insulation material has
been kept away from the furnace.

The following warning applies to horizontally vented furnaces only.

3. The furnace needs air for combustion in order to operate properly

and safely. Do not block or obstruct air openings on the furnace, air
openings  to  the  area  where  the  furnace  is  installed,  or  spaces
around the furnace.

4. Follow the instructions exactly as shown on the 

Operating instruc-

tion label

 on the furnace or the 

Start-up and shut-down 

instructions

of this manual when lighting the furnace or turning the furnace off.

 WARNING

Cancer and Reproductive Harm – www.P65Warnings.ca.gov

 WARNING

FIRE OR EXPLOSION HAZARD - 

Failure to follow safety warnings

exactly could result in serious injury, death, or property damage.

— Do not store or use gasoline or other flammable vapors and

liquids in the vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone (includ-

ing cell phone) in your building.

Leave the building immediately.

Immediately call your gas supplier from a neighbor’s phone. Fol-

low the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, 

service agency or the gas supplier.

!

!

 WARNING

FIRE OR EXPLOSION HAZARD
This furnace is designed and approved for use with Natural Gas and
(LP) Propane Gas ONLY. DO NOT BURN ANY LIQUID FUEL OR
SOLID FUEL IN THIS FURNACE.
Burning any unapproved fuel will result in damage to the furnace heat
exchanger, which could result in Fire, Personal Injury, and/or Property
Damage.

 WARNING

CARBON-MONOXIDE POISONING HAZARD
Failure to follow instructions could result in severe personal injury or
death due to carbon-monoxide poisoning, if combustion products infil-
trate into the building. 
Check that all openings in the outside wall around the vent (and air
intake) pipe(s) are sealed to prevent infiltration of combustion prod-
ucts into the building. 
Check that furnace vent (and air intake) terminal(s) are not obstructed
in any way during all seasons.

!

!

Summary of Contents for RGF1L P Series

Page 1: ...or when insulation is added to be sure that the insulation material has been kept away from the furnace The following warning applies to horizontally vented furnaces only 3 The furnace needs air for c...

Page 2: ...ce agency Examine the furnace as outlined below in Steps 1 to 8 before each heat ing season See Figures 1 to 4 for visual reference Figure 1 Component Location 80 Single and Two Stage Models Figure 2...

Page 3: ...ens and ignition occurs A short time later the blower starts and dis tributes the warm air throughout the home When the temperature set ting on your thermostat is reached the gas valve closes the main...

Page 4: ...me the external air filters are changed the following items must be visually inspected Check combustion air and vent pipe for blockage or leakage Check all components to ensure they are in good condit...

Page 5: ...port in the blower compartment door The control continuously monitors its own operation and the operation of the system If a failure occurs the LED indicates the failure code If the failure is interna...

Page 6: ...1010352 UUM N 0121 6 Johnson Controls Ducted Systems Notes...

Page 7: ...m warm air temperature and or with out adequate air circulation 3 The product is installed so that combustion air is not contaminated by compounds of chlorine fluorine or other damaging chemical vapor...

Page 8: ...ct 5 Labor or other costs incurred for diagnosing repairing removing installing shipping servicing or handling of defective replacement parts 6 Products removed from their original location for reinst...

Reviews: