Engineering manual - SAB 193-233-283 S A-frame (including ATEX)
76/168
008831 en 2020.10
5.2
Allowable flange loads
In any screw compressor installation, suction and discharge lines should be supported in pipe
hangers (preferably within 2 ft of vertical pipe run) so that the lines will not move if disconnected
from the compressor, see Table 12 and Table 13.
Noz. size
Nps
Torque (ft-lbf)
Torque {Nm]
Axial
Vert.
Lat.
Axial
Vert.
Lat.
M
R
M
C
M
L
M
R
M
C
M
L
1
25
25
25
34
34
34
1.25
25
25
25
34
34
34
1.5
50
40
40
68
54
54
2
100
70
70
136
95
95
3
250
175
175
339
237
237
4
400
200
200
542
271
271
5
425
400
400
576
542
542
6
1000
750
750
1356
1017
1017
8
1500
1000
1000
2034
1356
1356
10
1500
1200
1200
2034
1627
1627
Table 12: Allowable flange loads
Noz. size
Nps
Load (lbf)
Load [N]
Axial
Vert.
Lat.
Axial
Vert.
Lat.
P
V
C
V
L
P
V
C
V
L
1
50
50
50
222
222
222
1.25
50
50
50
222
222
222
1.5
100
75
75
445
334
334
2
150
125
125
667
556
556
3
225
250
250
1001
1112
1112
4
300
400
400
1334
1779
1779
5
400
450
450
1779
2002
2002
6
650
650
650
2891
2891
2891
8
1500
900
900
6672
4003
4003
10
1500
1200
1200
6672
5338
5338
Table 13: Allowable flange loads