Engineering manual - SAB 193-233-283 S A-frame (including ATEX)
008831 en 2020.10
95/168
6.10
Direction of rotation
The direction of rotation of the compressor is clockwise when looking at the coupling flange and
the compressor as illustrated in Fig. 71.
Fig. 71: Direction of rotation
6.11
Emergency stop
The compressor control system must be equipped with an emergency stop.
If the compressor is supplied with a UniSAB III control system, this emergency stop will be an in-
tegrated part of the system as shown in Fig. 72.
Emergency stop
Fig. 72: Emergency stop on the unit
The emergency device must be adjusted in such a way that after a stop instruction it stays in its
stop position until it is deliberately reset.
It must not be possible to block the emergency stop without a stop instruction being released.
It should only be possible to reset the emergency stop by a deliberate act. Resetting the emer-
gency stop must not cause the compressor to start operating, but only make it possible to restart
the compressor.
6.12
Other emergency stop requirements
•
It must be possible to operate the emergency stop by means of an easily recognisable and
visible manual handle to which there is free access.
•
The emergency stop must be able to stop any dangerous situation, as quickly as possible,
without this leading to any further danger.