background image

 Refer to the 

QuickLIT website

 for the most up-to-date version of this document.

TE-6800 Series Temperature Sensors Installation Instructions

1

Applications

The TE-68xx-xN00S Series provides temperature 
sensing in room wall mount applications. It allows local 
setpoint temperature adjustment and temporary 
occupancy override. 

A warmer/cooler dial is included on certain models for 
minor temperature adjustments from the setpoint. An 
occupancy override button allows the user to request a 
time-of-day scheduling override when the space is 
occupied outside of the normal occupied hours 
schedule. All sensors have DIP switches that enable or 
disable unit functions.

Depending on the model chosen, the wires connecting 
the sensor to the controller can be terminated using a 
screw terminal block or modular jack connection, 
offering wiring flexibility. All models include a Zone Bus 
access port for connecting accessories to access the 
6-pin modular jack. This feature allows a technician to 
commission or service the controller via the sensor.

   

Installation

Special Tools Needed

A 1/16 in. (1.5 mm) hex wrench or a 
Johnson Controls® T-4000-119 hex-head adjustment 
tool is required during installation.

Accessories

To install the TE-6800 Series Temperature Sensor on 
a wallbox requires accessory NS-WALLPLATE-0, 
ordered separately.

IMPORTANT:

The TE-6800 Series Temperature 

Sensor is intended to provide an input to equipment 
under normal operating conditions. Where failure or 
malfunction of the sensor could lead to personal 
injury or property damage to the controlled 
equipment or other property, additional precautions 
must be designed into the control system. 
Incorporate and maintain other devices, such as 
supervisory or alarm systems or safety or limit 
controls, intended to warn of or protect against 
failure or malfunction of the sensor.

IMPORTANT :

Le TE-6800 Series Temperature 

Sensor est destiné à transmettre des données 
entrantes à un équipement dans des conditions 
normales de fonctionnement. Lorsqu'une défaillance 
ou un dysfonctionnement du sensor risque de 
provoquer des blessures ou d'endommager 
l'équipement contrôlé ou un autre équipement, la 
conception du système de contrôle doit intégrer des 
dispositifs de protection supplémentaires. Veiller 
dans ce cas à intégrer de façon permanente 
d'autres dispositifs, tels que des systèmes de 
supervision ou d'alarme, ou des dispositifs de 
sécurité ou de limitation, ayant une fonction 
d'avertissement ou de protection en cas de 
défaillance ou de dysfonctionnement du sensor.

TE-6800 Series Temperature Sensors

Installation Instructions

TE-68xx-xN00S

Part No. 24-10409-1, Rev. F

Issued February 2016

2 4 - 1 0 4 0 9 - 1 ,   R e v .   F

Summary of Contents for TE-6800 Series

Page 1: ... Temperature Sensor on a wallbox requires accessory NS WALLPLATE 0 ordered separately IMPORTANT The TE 6800 Series Temperature Sensor is intended to provide an input to equipment under normal operating conditions Where failure or malfunction of the sensor could lead to personal injury or property damage to the controlled equipment or other property additional precautions must be designed into the ...

Page 2: ...e Note Confirm that the mounting base is positioned with the proper edge up The mounting base is positioned properly when the security screw is located on the top edge of the base 5 Secure the mounting base to the wall using the appropriate mounting hardware field furnished 6 Set DIP switches for the desired operation See Setup and Adjustments and Internal Wiring Diagrams for additional informatio...

Page 3: ...Figure 5 for an explanation of the Light Emitting Diode LED and Push Button PB modes Make connections pairing the following wires sensor Terminal 1 and Terminal 2 setpoint Terminal 3 and Terminal 4 Zone Bus and Common COM Terminals 6 and 7 Shielding is not required If used follow the system controller s recommendations for grounding the shield Note The Manual Override PB does not respond when the ...

Page 4: ...rnal wiring diagram with DIP switches set as shown on the right LED Mode OFF and Manual Override push button enabled ON term_bloc2 Not Connected Modular Jack Pin Numbers Figure 4 Terminal Block Location and Wiring Table 1 Terminal Block Wiring Part 1 of 2 Terminal Signal Designation 1 Temperature Sensor and Manual Override 2 Temperature Sensor Common 3 Setpoint Common and LED Common 4 Setpoint 5 2...

Page 5: ...tor into the 8 pin jack on the back of the TE 6800 Temperature Sensor to prevent damaging the modular jack Table 2 Modular Jack Pin Designations Modular Jack Pin Number Signal Designation 1 LED and Manual Override 2 Setpoint 3 Temperature Sensor and Manual Override 4 Temperature Sensor Common 5 24 VAC 15 VDC VMA only 1 1 The 15 VDC power supply is used only when a TE 6800 Series sensor is connecte...

Page 6: ...rary Occupancy mode vs Unoccupied mode at the controller Check the setpoint settings 4 Confirm DIP switch positions if the LED remains on or is dim the room sensor reading is outside of the normal range for the space being sensed Note Make sure the DIP switch setting is correct for the controller used with the TE 6800 5 Replace the TE 6800 if the troubleshooting suggestions fail to remedy the prob...

Page 7: ...jack connector Terminal Block Screw type terminals for 18 to 24 AWG wire Zone Bus Access 6 pin connector with front bottom access for a laptop with HVAC PRO software and CVTPRO converter Manual Override Integral momentary push button DIP switch selectable LED Light Green LED light indicates two modes of operation VMA1200 and VMA1400 Series controllers only Ambient Operating Conditions 32 to 131 F ...

Page 8: ... nominal and conform to acceptable industry standards For application at conditions beyond these specifications consult the local Johnson Controls office Johnson Controls Inc shall not be liable for damage resulting from misapplication or misuse of its products European Single Point of Contact NA SA Single Point of Contact APAC Single Point of Contact JOHNSON CONTROLS WESTENDHOF 3 45143 ESSEN GERM...

Reviews: