Table 61: Approximate unit weight including motor for flooded evaporator units - lb (kg)
Shells
Compressor
Shipping weight lb (kg)
Operating weight lb (kg) Estimate refrigerant charge lb (kg)
K-K
H9
28,530 (12,941)
36,000 (16,330)
2,925 (1,327)
K-K
K1
31,100 (14,107)
36,200 (16,420)
3,248 (1,473)
K-O
H9
34,483 (15,641)
44,776 (20,310)
3,260 (1,479)
M-M
H9
34,200 (15,513)
43,600 (19,777)
3,665 (1,662)
M-M
K1,K2
38,300 (17,373)
47,100 (21,365)
3,665 (1,662)
M-U
K2
45,178 (20,493)
58,017 (26,317)
3,540 (1,606)
N-N
K1,K2
28,530 (12,941)
50,800 (23,043)
4,225 (1,916)
N-N
K3
48,000 (21,773)
54,100 (24,540)
4,225 (1,916)
P-P
K1,K2
41,500 (18,824)
51,900 (23,542)
3,855 (1,749)
Q-Q
K1,K2
45,300 (20,548)
56,800 (25,764)
4,255 (1,930)
Q-Q
K3
46,000 (20,866)
60,200 (27,307)
4,255 (1,930)
R-R
K3
52,800 (23,950)
70,300 (31,888)
4,660 (2,114)
R-R
K4
53,000 (24,041)
70,600 (32,024)
4,785 (2,170)
S-S
K4
59,000 (26,762)
76,300 (34,610)
4,940 (2,241)
S-V
K4
60,100 (27,261)
81,300 (36,878)
5,500 (2,495)
X-T
K4
59,200 (26,853)
80,000 (36,288)
5,125 (2,325)
X-X
K4
66,000 (29,938)
87,000 (39,463)
5,625 (2,552)
W-W
K7
79,500 (36,061)
104,000 (47,174)
6,900 (3,130)
Z-Y
K7
95,300 (43,228)
123,015 (55,800)
6,555 (2,973)
Z-Z
K7
80,500 (36,515)
105,000 (47,628)
6,275 (2,846)
Note:
Refrigerant charge quantity and weights vary based on tube count, configuration, and
chiller performance. Use for reference only. Refer to
YORKworks Performance Page
or chiller
nameplate for actual charge requirement.
Table 62: Approximate unit weight including motor for hybrid falling film evaporator units -
lb (kg)
Shells
Compressor
Shipping weight lb (kg)
Operating weight lb (kg) Estimated refrigerant charge lb
(kg)
A-A
Q3
12,850 (5,584)
14,419 (6,540)
695 (315)
C-C
Q3, Q4
14,570 (6,609)
16,848 (7,642)
875 (397)
C-C
Q5
15,000 (6,804)
17,278 (7,837)
875 (397)
D-D
Q4
17,000 (7,711)
20,051 (9,095)
1,180 (535)
D-D
Q5
17,410 (7,897)
20,461 (9,281)
1,180 (535)
E-E
Q5, Q6, Q7, P7 18,700 (8,482)
21,700 (9,843)
1,120 (508)
F-F
Q5, Q6, Q7, P7 19,220 (8,718)
23,142 (10,497)
1,415 (642)
G-E
P8, P9
20,640 (9,362)
24,036 (10,903)
1,320 (599)
H-F
P8, P9
23,540 (10,678)
28,083 (12,738)
1,775 (805)
I-K
H9
28,849 (13,086)
34,078 (15,458)
1,820 (826)
K-K
H9
28,850 (13,086)
34,079 (15,458)
1,820 (826)
I-K
K1
31,350 (14,220)
35,145 (15,942)
1,820 (826)
M-M
K1, K2
34,520 (15,000)
46,055 (20,013)
2,300 (1,043)
N-N
K1, K2
41,273 (18,721)
49,605 (22,501)
2,650 (1,202)
N-N
K3
48,380 (21,945)
52,905 (23,998)
2,650 (1,202)
P-P
K1, K2
41,950 (19029)
51,595 (23,403)
3,100 (1,406)
Q-Q
K1, K2
45,800 (20,775)
56,545 (25,649)
3,500 (1,588)
Q-Q
K3
46,500 (21,092)
59,945 (27,191)
3,500 (1,588)
Note:
Refrigerant charge quantity and weights will vary based on tube count, configuration,
and chiller performance. Use for reference only. Refer to
YORKworks Performance Page
or chiller
nameplate for actual charge requirement.
Model YK (Style G) Centrifugal Liquid Chiller
62
Summary of Contents for YORK YK Series
Page 2: ...2 Model YK Style G Centrifugal Liquid Chiller...
Page 14: ...Figure 3 Long term storage tube side Model YK Style G Centrifugal Liquid Chiller 14...
Page 19: ...Figure 6 Neoprene isolators in mm 19 Model YK Style G Centrifugal Liquid Chiller...
Page 20: ...Figure 7 Spring isolators in mm Model YK Style G Centrifugal Liquid Chiller 20...
Page 21: ...Figure 8 Spring isolators continued in mm 21 Model YK Style G Centrifugal Liquid Chiller...