background image

Maintenance

1.Open the lnlet Grille

2.Detach the standard air filter

3.Attach Air Purifying Filter

4.Attach the standard air filter

(Necessary installation)

5.Close the Inlet Grille

Close the Grille surely

Slide the knob slightly upward to 
release the filter, then withdraw it.

Put air purifying filter appliances into the
right and left filter frames.

Detach old Air Purifying Filter

NOTE:

The photocatalyst air purifying filter will be solarized in fixed
time. In normal family, it will be solarized every 6 months.

Prop up the inlet grille by using a

 small device named grille-support 

ATTENTION:
The white side of the photocatalyst air purifying

filter face outside,and the black side face the unit.

The green side of the bacteria-killing medium air 

and the white side face the unit.

Please keep the bacteria-killing medium air purifying filter in

avoid long time directly sunshine

when you stop using it,or its ability of sterilization will be

reduced.

The bacteria-killing medium air purifying filter will be used 
for a long time,no need for replacement. But in the period 
of using them ,you should remove the dust frequently by 

Replacement of Air Purifying Filter

which located in the right side of

 the indoor unit. 

purifying filter face outside,

using vacuum cleaner or flaping them lightly,otherwise ,

its performance will be affected. 

the cool and dry conditions

(NOTE: Air purifying filter is optional part)

 

YSCC/H07/09/12FSAADG

                   System Configuration

                                                                                                       

                                                         

Domestic Air Conditioner 

30

Summary of Contents for YORK YSCC/H09FSAADG

Page 1: ...ic It does not contain warnings or cautions to advise non technical individuals of potential dangers in attempting to service a product Products powered by electricity should be serviced or repaired only by experienced professional technicians Any attempt to service or repair the product or products dealt with in this service information by anyone else could result in serious injury or death WARNI...

Page 2: ...ction 3 Specifications 4 Printed Circuit Board Connector Wiring Diagram 5 Functions and Control 6 System Configuration 7 Service Diagnosis 8 9 10 1 Piping diagrams 10 2 Wiring diagrams 10 3 Circuit diagrams 10 4 Dimensional drawing 10 5 Center of gravity 10 6 Operation range 10 7 Accessories 10 8 Description of the unit model s cooling rules 55 56 58 59 61 63 64 64 YSCC H07 09 12FSAADG ...

Page 3: ... special tools for quick cleaning of the inside of the air conditioner Anti mold filter Catches most small particles and remove unpleasant odors effectively Sleep mode The setting temperature and the indoor noise can be adjusted to a more comfortable level when you set the sleep mode during night sleep ESF filter Trap harmful dust and remove unpleasant odors effectively Auto mode According to the ...

Page 4: ...ing the equipment for a repair Working on the equipment that is connected to a power supply can cause an electrical shook If it is necessary to supply power to the equipment to conduct the repair or inspecting the circuits do not touch any electrically charged sections of the equipment If the refrigerant gas discharges during the repair work do not touch the discharging refrigerant gas The refrige...

Page 5: ...lder in an enclosed room can cause oxygen deficiency 2 1 2 Cautions Regarding Products after Repair Warning Be sure to use parts listed in the service parts list of the applicable model and appropriate tools to conduct repair work Never attempt to modify the equipment The use of inappropriate parts or tools can cause an electrical shock excessive heat generation or fire When relocating the equipme...

Page 6: ...gerant system If air enters the refrigerating system an excessively high pressure results causing equipment damage and injury If the refrigerant gas leaks be sure to locate the leak and repair it before charging the refrigerant After charging refrigerant make sure that there is no refrigerant leak If the leak cannot be located and the repair work must be stopped be sure to perform pump down and cl...

Page 7: ...s are mounted and connected properly and if the connections at the soldered or crimped terminals are secure Improper installation and connections can cause excessive heat generation fire or an electrical shock If the installation platform or frame has corroded replace it Corroded installation platform or frame can cause the unit to fall resulting in injury Check the grounding and repair it if the ...

Page 8: ...he reader such as tips and tricks Caution Caution A caution is used when there is danger that the reader through incorrect manipulation may damage equipment loose data get an unexpected result or has to restart part of a procedure Warning Warning A warning is used when there is danger of personal injury Reference A reference guides the reader to other places in this binder or in this manual where ...

Page 9: ...15 7 5 5 196 1 20 20 WxHxD WxHxD 8 8 36 33 28 39 34 30 6 35 9 52 6 35 9 52 25 25 1 0 2 05 1 2 795x190x265 7000 2 64 9000 820 11 3 8 8 11 3 48 50 5 HZ V 60 60 220V H P 1 H P 1 3 3 5 5 2 9 795x190x265 3 85 0 11 0 11 6 7 235 3 6 1 215 7 5 5 196 1 0 6 3 x 4 0 3 x 1 7 8 0 6 3 x 4 0 3 x 1 7 8 YSCC H07 09 12FSAADG 7 ...

Page 10: ...10A Axial fan 0 21 930 340 614 780 245 540 16 1 568 3 26 7 19 4 23 9 5m 3413 1790 0 32 0 95 Rotary Compressor Rotary Compressor 39A162AD 44A222AJ R410A Axial fan 930 340 614 780 245 540 35 NMOC Ze Gles RB68EP or equivalent NMOC Ze Gles RB68EP or equivalent YSCC H07 09 12FSAADG ...

Page 11: ...FSAADG 1090 EER COP 3 21 16 10 5 20 white 6 7 235 3 6 1 215 7 5 5 196 1 25 WxHxD WxHxD 10 5 41 38 36 6 35 9 52 1 6 3 5 938x191x265 12000 12 5 52 HZ V 60 220V H P 1 3 5 4 9 0 6 3 x 4 0 3 x 6 1 10 YSCC H07 09 12FSAADG 9 ...

Page 12: ...1 00 16 1 568 3 16 33 37 1790 3 19 705 52 52 R410A Axial fan 0 37 930 340 714 780 245 640 26 7 19 4 23 9 5m 3413 Rotary Compressor YSCC H07 09 12FSAADG NMOC Ze Gles RB68EP or equivalent 44A302AL 10 ...

Page 13: ...er input 2 CN2 connector for terminal block 3 CN3 connector for transformer output 4 CN5 or CN5 1 connector for up and down step motor 5 CN6 connector for ambient temp sensor and piping temp sensor 6 CN7 connector for receiver display 7 CN8 connector for AC fan feedback motor 8 CN9 connector for AC fan motor CN8 CN7 CN5 CN5 1 CN6 CN9 CN1 CN2 YSCC H07 09 12FSAADG 11 ...

Page 14: ...en cooling mode fan mode and heating mode according to the change of the indoor ambient temperature But the automatic conversion between cooling mode and heating mode must be conducted after 15 minutes 5 1 2 Indoor temperature control Temperature control range 16 30 Temperature control precision 1 Compressor can t be controlled by temperature sensor within 2 minutes after it starts 5 1 2 1 Cooling...

Page 15: ...ration prevention When the temp of coil pipe is above 62 compressor and outlet air stop running 10 seconds later and inlet air runs as the temp sensor is off When compressor stands by for 3 minute and the temp of coil pipe is below 60 the unit can be started again Protection of frost is available disable in test run or heating mode In order to prevent the indoor heat exchanger from freezing in ref...

Page 16: ...mpressor does After compressor stops runnig the 4 way valve continues running for 2 minutes and then stops If changing the unit from heating to cooling the 4 way valve is shut off 2 minutes later and compressor is started 3 minutes later 5 1 5 1 Cold draft prevetion 5 1 5 1 1 Compressor is interrupted during the defrosting operation and continues to run after defrosting is completed When the indoo...

Page 17: ...usly and the temp of indoor coil pipe is below 38 5 1 5 3 1 2 Compressor runs20minutes continuously and the temp of indoor coil pipe decreases 1 per 6 minutes and this operation repeats 3 times and the temp of coil pipe is below 38 and 5 minutes later after compressor is restarted 5 1 5 3 1 3 When compressor runs over 3 hours in total and over 20 minutes continuously and after the temp of indoor c...

Page 18: ... 1 7 Sleep function the timer indicator lights up 5 1 7 1 In cooling defrosting mode the temp setting increases 1 one hour later after start up After another hour the temp setting increase by more 1 and then run continuously for another 6 hours and then close 5 1 7 2 In heating mode the temp setting decrease 2 one hour after start up After another hour the temp setting decrease by more 2 After 3 h...

Page 19: ... is available If the buzzer rings 2 times the the auto recovery function of power on is unavailable If there is no EEPROM the unit is taken off the off function of the memory function of power down But the memory function of power down can also be set on off and the data is the default value of chip 5 1 11 Alarm from indoor fan motor 2 minutes later after the indoor fan motor is charged and the im...

Page 20: ...3062 62 1807 58 2405 1 24 1 19 6 62 7992 58 9853 55 3351 1 22 1 17 7 59 4984 55 9729 52 5917 1 20 1 15 8 56 3905 53 1320 50 0006 1 17 1 13 9 53 4631 50 4521 47 5523 1 15 1 11 10 50 7048 47 9230 45 2384 1 13 1 09 11 48 1049 45 5355 43 0505 1 10 1 07 12 45 6534 43 2808 40 9813 1 08 1 04 13 43 3410 41 1509 39 0236 1 05 1 02 14 41 1592 39 1381 37 1708 1 03 1 00 15 39 0998 37 2355 35 4167 1 00 0 98 16 ...

Page 21: ...327 1 68 1 60 50 8 2713 7 7345 7 2237 1 73 1 64 51 7 9531 7 4280 6 9291 1 77 1 68 52 7 6489 7 1353 6 6480 1 81 1 72 53 7 3580 6 8556 6 3797 1 85 1 76 54 7 0796 6 5884 6 1237 1 90 1 79 55 6 8131 6 3329 5 8793 1 94 1 83 56 6 5581 6 0887 5 6459 1 99 1 87 57 6 3140 5 8552 5 4230 2 03 1 91 58 6 0802 5 6318 5 2100 2 07 1 95 59 5 8563 5 4181 5 0065 2 12 1 99 60 5 6417 5 2136 4 8120 2 16 2 03 61 5 4361 5 ...

Page 22: ...1 3603 3 91 3 52 96 1 6643 1 4810 1 3163 3 97 3 56 97 1 6138 1 4347 1 2739 4 02 3 61 98 1 5650 1 3900 1 2331 4 08 3 66 99 1 5180 1 3470 1 1937 4 13 3 70 100 1 4726 1 3054 1 1559 4 19 3 75 101 1 4287 1 2654 1 1194 4 24 3 80 102 1 3864 1 2268 1 0842 4 30 3 84 103 1 3455 1 1895 1 0503 4 36 3 89 104 1 3060 1 1535 1 0176 4 42 3 94 105 1 2679 1 1188 0 9860 4 47 3 98 106 1 2310 1 0853 0 9556 4 53 4 03 10...

Page 23: ...023 58 9863 1 66 1 54 14 66 3463 61 0123 56 0565 1 64 1 52 13 62 8755 57 9110 53 2905 1 62 1 51 12 59 6076 54 9866 50 6781 1 60 1 49 11 56 5296 52 2278 48 2099 1 58 1 47 10 53 6294 49 6244 45 8771 1 56 1 46 9 50 8956 47 1666 43 6714 1 54 1 44 8 48 3178 44 8454 41 5851 1 51 1 42 7 45 8860 42 6525 39 6112 1 49 1 40 6 43 5912 40 5800 37 7429 1 47 1 39 5 41 4249 38 6207 35 9739 1 45 1 37 4 39 3792 36 ...

Page 24: ...8 5496 0 84 0 83 29 8 7942 8 4964 8 2013 0 87 0 86 30 8 4583 8 1621 7 8691 0 91 0 90 31 8 1371 7 8428 7 5522 0 95 0 93 32 7 8299 7 5377 7 2498 0 98 0 97 33 7 5359 7 2461 6 9611 1 02 1 00 34 7 2546 6 9673 6 6854 1 06 1 04 35 6 9852 6 7008 6 4222 1 10 1 07 36 6 7273 6 4459 6 1707 1 13 1 11 37 6 4803 6 2021 5 9304 1 17 1 14 38 6 2437 5 9687 5 7007 1 21 1 18 39 6 0170 5 7454 5 4812 1 25 1 22 40 5 7997...

Page 25: ...533 1 7064 1 5697 2 78 2 58 75 1 7974 1 6533 1 5194 2 83 2 63 76 1 7434 1 6021 1 4710 2 88 2 67 77 1 6913 1 5528 1 4243 2 92 2 71 78 1 6409 1 5051 1 3794 2 97 2 75 79 1 5923 1 4592 1 3360 3 02 2 80 80 1 5454 1 4149 1 2942 3 07 2 84 81 1 5000 1 3721 1 2540 3 12 2 88 82 1 4562 1 3308 1 2151 3 17 2 93 83 1 4139 1 2910 1 1776 3 22 2 97 84 1 3730 1 2525 1 1415 3 27 3 01 85 1 3335 1 2153 1 1066 3 32 3 0...

Page 26: ... 0 6482 0 5792 4 51 4 07 108 0 7059 0 6308 0 5632 4 57 4 12 109 0 6877 0 6140 0 5478 4 63 4 16 110 0 6700 0 5977 0 5328 4 69 4 21 111 0 6528 0 5820 0 5183 4 74 4 26 112 0 6361 0 5667 0 5043 4 80 4 31 113 0 6200 0 5518 0 4907 4 86 4 36 114 0 6043 0 5374 0 4775 4 92 4 41 115 0 5891 0 5235 0 4648 4 98 4 45 116 0 5743 0 5100 0 4524 5 04 4 50 117 0 5600 0 4968 0 4404 5 10 4 55 118 0 5460 0 4841 0 4288 ...

Page 27: ... method of using it In order to meet this expectation of the users giving sufficient explanations taking enough time can be said to reduce about 80 of the requests for servicing However good the installation work is and however good the functions are the customer may blame either the room air conditioner or its installation work because of improper handling The installation work and handing over o...

Page 28: ...isplay or unclear display during operation indicates the ries have been used up Please change batteries If the remote controller can t run normally during operation reload several minutes later batte remove the batteries and Remove the batteries in case unit won t be in usage for a long period If there are any display after taking out just need to press reset key Hint Loading of the battery please...

Page 29: ... flap Pos 1 Pos 2 Pos 3 Pos 4 Pos 5 Auto swing 1 Status display of air flow When restart after remote turning off the remote memorize the previous Move the vertical blade by a knob on air to adjust left and right direction referring to Fig 2 Left and right air flow adjustment manual Cautions When adjusting the flap by hand turn off the unit When humidity is high condensate water might occur adjust...

Page 30: ...1 hours temp rises by 1 futher The unit will run for further 6 hours then stops Temp is higher than temp setting so that room temperature won t be too low for your sleep 1 hours after SLEEP mode starts temp will become 2 lower than temp setting After another 1 hours temp decrease by 2 futher After more another 3hours temp rises by 1 futher The unit will run for further 3 hours then stops Temp is l...

Page 31: ...fore the setting of healthy airflow function Notice Do not direct the flap by hand Otherwise the grille will run incorrectly If the grille is not run correctly stop for a minute and then start adjusting by remote controller blows direct to the body 2 In heating it is better to select the 3 In cooling it is better to select the mode mode Setting of proper room temperature Close doors and windows du...

Page 32: ...rifying filter face outside and the black side face the unit The green side of the bacteria killing medium air and the white side face the unit Please keep the bacteria killing medium air purifying filter in avoid long time directly sunshine when you stop using it or its ability of sterilization will be reduced The bacteria killing medium air purifying filter will be used for a long time no need f...

Page 33: ...yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Take fresh air occasionally especially when gas appliance is running at the same time PROHIBITION STRICT ENFORCEMENT Do not operate the switch with wet hand PROHIBITION PROHIBITION PROHIBITION PROHIBITION PROHIBITION Do not install the unit near a fireplace or other heating apparatus C...

Page 34: ...asily reached 5 The wiring method should be in line with the local wiring standard 4 The distance between the indoor unit and the floor should be more than 2m 3 If the fuse on PC board is broken please change it with a fuse type T 3 15A 250V 11 The wiring diagram is attached inside the machine 2 If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar...

Page 35: ...operates Check the indoor PCB Check to make sure that the indoor PCB is broken Equipment operates but does not cool or does not heat only for heat pump Diagnosis by service port pressure and operating current Check for insufficient gas Large operating noise and vibrations Check the installation condition Check to make sure that the required spaces for installation specified in the Technical Guide ...

Page 36: ...E1 Room temperature sensor failure CN6 E2 Heat exchange sensor failure CN6 NO Check the value of the sensor to see whether the sensor is damaged or not YES The indoor PCB is broken replace with new indoor PCB Sensor is broken replace it with new sensor Pull the sensor out of the mainboard 1 Measure the value of resistance Between its two jumpers 2 Measure the temperature at the room temperature se...

Page 37: ...YSCC H07 09 12FSAADG 35 ...

Page 38: ...4 2113 2132 2091 1904 1718 1595 1399 26 7 19 4 2355 2265 2315 2152 2050 1899 1776 1552 30 22 2632 2484 2672 2378 2248 2118 1946 1799 32 23 2732 2468 2678 2349 2292 2183 2055 1827 32 24 2811 2542 2756 2421 2363 2251 2120 1890 YSCC H07FSAADG performance curves cooling value temperature table outdoor temp humidity 46 Cooling value Temp curves 500 1000 1500 2000 2500 3000 1 8 1 2 1 8 1 4 2 0 1 5 2 2 1...

Page 39: ...9 26 7 19 4 2945 2855 2905 2742 2640 2489 2366 2142 30 22 3222 3074 3262 2968 2838 2708 2536 2389 32 23 3322 3058 3268 2939 2882 2773 2645 2417 32 24 3401 3132 3346 3011 2953 2841 2710 2480 YSCC H09FSAADG performance curves cooling value temperature table outdoor temp humidity 46 Sensible cooling value temp curves 500 1000 1500 2000 2500 1 8 1 2 1 8 1 4 2 0 1 5 2 2 1 6 2 5 1 8 2 6 7 1 9 4 3 0 2 2 ...

Page 40: ... 26 7 19 4 3945 3855 3900 3740 3500 3489 3366 3140 30 22 4220 4074 4262 2968 3838 3708 3536 3380 32 23 4322 4058 4268 3940 3882 3773 3645 3415 32 24 4400 4132 4346 4011 3953 3841 3710 3480 YSCC H12FSAADG performance curves cooling value temperature table outdoor temp humidity 46 Sensible cooling value temp curves 2500 3500 4000 4500 1 8 1 2 1 8 1 4 2 0 1 5 2 2 1 6 2 5 1 8 2 6 7 1 9 4 3 0 2 2 3 2 2...

Page 41: ...6 403 400 625 640 724 807 900 30 22 445 422 418 647 663 789 864 939 32 23 451 414 407 606 642 787 884 921 32 24 530 484 456 627 654 800 898 956 outdoor temp humidity 46 power consumption value temp table YSCC H07FSAADG performance curves Power consumption temp curves 150 350 550 750 950 1150 1 8 1 2 1 8 1 4 2 0 1 5 2 2 1 6 2 5 1 8 2 6 7 1 9 4 3 0 2 2 3 2 2 3 3 2 2 4 Indoor temp DB WB 18 20 25 32 3...

Page 42: ...1042 1025 30 22 640 717 703 842 858 884 1069 1154 32 23 646 709 682 801 837 982 1079 1176 32 24 665 719 691 712 849 995 1093 1191 outdoor temp humidity 46 power consumption value temp table YSCC H09FSAADG performance curves Power consumption temp curves 400 600 800 1000 1200 1400 1 8 1 2 1 8 1 4 2 0 1 5 2 2 1 6 2 5 1 8 2 6 7 1 9 4 3 0 2 2 3 2 2 3 3 2 2 4 Indoor temp DB WB Power consumption w 18 20...

Page 43: ...7 19 4 798 861 924 987 1090 1113 1239 30 22 838 904 969 1035 1100 1166 1297 32 23 858 925 992 1059 1126 1192 1326 YSCC H12FSAADG performance curves Power consumption value temp table W Outdoor temp humidity 46 Power consumption temp curves 700 800 900 1000 1100 1200 1300 1400 1500 1 8 1 2 2 0 1 5 2 2 1 6 2 5 1 8 2 6 7 1 9 4 3 0 2 2 3 2 2 3 Indoor temp DB WB Power consumption W 18 20 25 32 35 40 43...

Page 44: ...2 1207 1286 25 1029 1160 1272 30 1401 1573 1644 35 1714 1841 1920 40 2026 2106 2197 45 2380 2550 2591 YSCC H07FSAADG performance curves cooling discharge pressure table indoor temp Cooling discharge pressure 500 1000 1500 2000 2500 3000 15 25 30 35 40 45 Outdoor temp Discharge pressure 16 19 22 42 YSCC H07 09 12FSAADG ...

Page 45: ...10 1322 30 1451 1623 1694 35 1764 1891 1970 40 2076 2156 2247 45 2430 2600 2641 YSCC H09FSAADG performance curves cooling discharge pressure table indoor tem p Cooling discharge pressure 500 1000 1500 2000 2500 3000 15 25 30 35 40 45 Outdoor tem p D isch a rg e p re ssu re 16 19 22 YSCC H07 09 12FSAADG 43 ...

Page 46: ...1824 2371 30 1411 1882 2446 35 1440 1920 2496 40 1498 1997 2596 43 1526 2035 2646 YSCC H12FSAADG performance curves cooling discharge pressure table Kpa indoor tem p Cooling discharge pressure 800 1300 1800 2300 2800 18 25 30 35 40 43 Outdoor tem p D is c harge pres s ure 21 27 32 44 YSCC H07 09 12FSAADG ...

Page 47: ...1 27 32 18 294 399 524 25 301 408 536 30 311 421 553 35 318 430 565 40 331 448 588 43 338 457 600 YSCC H07FSAADG performance curves cooling suction pressure table Kpa indoor temp 280 380 480 580 680 18 25 30 35 40 43 Outdoor temp Suction pressure 21 27 32 Cooling suction pressure YSCC H07 09 12FSAADG 45 ...

Page 48: ...1 653 25 581 660 664 30 585 666 663 35 594 668 684 40 632 710 726 45 660 742 757 YSCC H09FSAADG performance curves cooling suction pressure table indoor tem p 500 600 700 800 15 25 30 35 40 45 Outdoor tem p S u ctio n p re ssu re 16 19 22 Cooling suction pressure YSCC H07 09 12FSAADG 46 ...

Page 49: ...44 25 321 428 556 30 331 441 573 35 338 450 585 40 351 468 608 43 358 477 620 YSCC H12FSAADG performance curves cooling suction pressure table Kpa indoor tem p 300 400 500 600 700 18 25 30 35 40 43 Outdoor tem p S uc tion pres s ure 21 27 32 Cooling suction pressure 47 YSCC H07 09 12FSAADG ...

Page 50: ...8 5 Sound level YSCC H07FSAADG YSCC H07FSAADG pressure M L 36 33 28 48 220V 60HZ YSCC H07 09 12FSAADG 48 ...

Page 51: ...YSCC H09FSAADG pressure M L 39 34 30 YSCC H09FSAADG 50 220V 60HZ 49 YSCC H07 09 12FSAADG ...

Page 52: ...YSCC H12FSAADG pressure M L 39 35 31 YSCC H12FSAADG 39 220V 60HZ YSCC H07 09 12FSAADG 50 ...

Page 53: ...ller on a wall place where the indoor unit can receive signals when the uorescent lamps in the room are lightened Outdoor Unit Place which is less affected by rain or direct sunlight and is suf ciently ventilated Place possible to bear the unit where vibration and noise are not increased Place where discharged wind and noise do not cause a nuisance to the neighbors Place where a distance marked is...

Page 54: ...o the dent of heat insulation materials of indoor unit 2 Insert the indoor outdoor electric cable from backside of indoor unit and pull it out on the front side then connect them 3 Coat the aring seal face with refrigerant oil and connect pipes Cover the connection part with heat insulation materials closely and make sure xing with adhesive tape Fixing the indoor unit body Hang surely the unit bod...

Page 55: ...refrigerant pipes and indoor unit using a vacuum pump then Spanner Forced fastening without careful centering may damage the threads and cause a leakage of gas Pipe Diameter Fastening torque Liquid side6 35mm 1 4 18N m Liquid Gas side9 52mm 3 8 42 N m Gas side 12 7mm 1 2 55N m Gas side 15 88mm 5 8 60 N m Max Elevation In case the elevation A is more than 5m oil trap shoud be installed every 5 7m M...

Page 56: ...ge breaker 4 Flare pipe Lean Damage of are Crack Partial Too outside t c e r r o c n I t c e r r o C On Drainage It becomes high midway The gap with the ground is too smal There is the bad smell from a ditch It waves The end is imm ersed in water Please install the drain hose so as to be downward slope without fail Please don t do the drainage as shown below Please pour water in the drain pan of t...

Page 57: ...Domestic air conditioner Piping diagrams YSCC H07 09 12FSAADG 55 ...

Page 58: ...d lines 1 HEAT PUMP 2 COOLING ONLY 1 No dotted lines marked with R RED BR BROWN B BLACK BL BLUE W WHITE Y G YELLOW GREEN The ion generator marked with is optional 3 ION GENERATOR 2 The CT marked with may not be used in some FU S E TO OUTDOOR UNIT cooling only models 56 YSCC H07 09 12FSAADG ...

Page 59: ...OR 2 There are no dotted lines on cool only type marked with Wire is connected from 4 marked with on terminal block to 1 TO INDOOR FRESH AIR MOTOR 4 way valve CAPACITOR CAPACITOR 1 See above for wiring of heat pump type NOTE 1 FRESH AIR MOTOR 3 Some of cool only type terminal block only have 1 2 and but no the parts 4 The parts are optional 2 Y G 3 YSCC H07 09 12FSAADG 57 ...

Page 60: ... 4 CN6 B4B XH 5V C16 0 1UF R17 4 7K R37 10K 12V R36 1K E2 4 7uF 16V E3 4 7uF 16V R40 1K R SRCK RCK SER COM3 COM2 R25 560 R27 560 1 CON7 1 CON8 GND 5V A B C D CT 50HZ PGO WF ST FLZ YJ HEAT R101 1K R102 1K R103 1K SW2 SW3 5 N1 2SC2412 N2 2SC2412 N3 2SC2412 P1 2SA1037AK P2 2SB1182 XT1 8M Frashair 1 2 3 4 5 6 7 8 CN7 S8B PH 89401 0810 C23 1nF E8 100uF 16V RED BLACK step m otor CT 50HZ WF FLZ ST YJ HEA...

Page 61: ...Dimensional drawings 10 4 Dimensional drawings YSCC H07 09FSAADG YSCC H12FSAADG YSCC H07 09 12FSAADG 59 ...

Page 62: ...Dimensional drawings YSCC H12FSAADG 5 4 2 840 0 8 7 640 9 52mm 3 8 YSCC H07 09FSAADG 5 4 2 840 0 8 7 540 9 52mm 3 8 YSCC H07 09 12FSAADG 60 ...

Page 63: ...YSCC H07 09FSAADG Indoor unit 10 5 Center of gravity 795 265 190 320 115 89 780 540 302 126 245 350 YSCC H07 09FSAADG Outdoor unit YSCC H07 09 12FSAADG 61 ...

Page 64: ...YSCC H12FSAADG Indoor unit 938 265 190 377 115 89 780 540 302 126 245 415 YSCC H12FSAADG Outdoor unit YSCC H07 09 12FSAADG 62 ...

Page 65: ...0 43 n w o d l l u p 0 3 20 18 10 0 16 23 32 10 20 30 indoor temp WB Notes The graphs are based on the following condition Equivalent piping length 7 5m Level difference 0m h g i h e t a r w o l f r i A Outdoor temp 10 6 Operation range 63 YSCC H07 09 12FSAADG ...

Page 66: ...10 7 Accessories R 03 dry battery 2 6 Plastic cap 4 Cover 1 4 Pipe supporting plate 1 Drain elbow 0 Steel nail Cushion YSCC H07 09 12FSAADG YSCC H07 09 12FSAADG 64 ...

Page 67: ...The end YSCC H07 09 12FSAADG ...

Reviews: