85-03-00954
70 |
P a g e
Maintenance and Diagnostics Helpful Hints
Components Location:
Manual Shutoff Ball Valve
: A manual shutoff ball valve is located in the left air gap adjacent to the glass frame left edge.
Use the glass latch tool to operate this ball valve.
Main Gas Valve
: The main gas valve is located on the left side of the firebox. An inspection panel is provided on the left
firebox wall that allows inspection of the gas valve, wiring and gas inlet connections.
Ignition Control Module:
The ignition Control Module is mounted on the right side on the floor. Access to the Ignition
Module is available through the Blower and Control Module Access panel.
Ignition Control Module Main Wire Harness
: The main wire harness which connects the Ignition Module to the main
gas valve, valve motor and rear burner solenoid valve runs below the firebox floor from the right side to the left side. Care
must be exercised not to pull or tug on this harness which may result in breakage of connection terminals on either ends.
Convection Blower
: The convection blower is mounted on the firebox right wall. Access to the convection blower is
available through the Blower and Control Module Access panel.
Accent Light:
The accent light is mounted in the firebox top center area. The accent light wire harness is run from the
light housing to the right side and then down to the ignition control module.
Master Switch and Sync Switch
: The Master switch and Sync switch are mounted on the right side bottom edge of the
glass frame on a small metal plate which can be removed to replace defective Master switch or Sync switch.
Rear Burner Air Shutter Control
: A rear burner air shutter control is located in the gap behind the Sync Switch. Operate
the rear burner air shutter using the glass latch tool.
Electrical Junction Box
: An electrical junction box is located on the right side of this appliance and is accessible through
the Convection Blower and Control Module access panel.
Gas Supply Inlet connection
: The main gas supply line enters this appliance on the left side and is accessible through