background image

4

©2013 Johnson Level & Tool - Rev. 1 

4. Location of Part/Components

1.  LCD Display
2.  Power On/Measure/

Continuous Measure Button

3.  Function Button

Add

Subtract

Area
Volume

Indirect/Pythagoras

4.  Clear/Power Off Button
5.  Warning Label
6.  Battery Cover
7.  Laser Emitting Window
8.  Receiver Window

1

2

5

6

7

8

3
4

7349H-English_Manuals  9/6/13  1:55 PM  Page 4

Summary of Contents for 40-6006

Page 1: ...ore using the instrument Save this instruction manual for future use This is a Class II laser tool and is manufactured to comply with CRF 21 parts 1040 10 and 1040 11 as well as international safety rule IEC 285 The laser also complies with EMC Test according to EN61000 6 3 2001 A11 2004 EN 6100 6 1 2011 EN 6100 4 2 EN 61000 4 3 EN 60825 FCC Test according to PART 15 7349H English_Manuals 9 6 13 1...

Page 2: ...Registration pg 19 1 Kit Contents Description for Model 40 6006 Qty Laser Distance Measure 1 AAA Alkaline Batteries 2 Instruction Manual with Warranty Card 1 Strap 1 Soft Sided Pouch 1 2 Safety Instructions Please read and understand all of the following instructions prior to using this tool Failure to do so may void warranty CAUTION Class II Laser Product Max Power Output 1mW Wavelength 640 660nm...

Page 3: ...e environments i e in the presence of gases or flammable liquids Keep the laser tool out of the reach of children and other untrained persons Do not attempt to view the laser beam through optical tools such as telescopes as serious eye injury may result Always turn the laser tool off when not in use or left unattended for a period of time Remove the battery when storing the tool for an extended ti...

Page 4: ...splay 2 Power On Measure Continuous Measure Button 3 Function Button Add Subtract Area Volume Indirect Pythagoras 4 Clear Power Off Button 5 Warning Label 6 Battery Cover 7 Laser Emitting Window 8 Receiver Window 1 2 5 6 7 8 3 4 7349H English_Manuals 9 6 13 1 55 PM Page 4 ...

Page 5: ...tive Laser Indicator 2 Measurement Reference Position 3 Sub Screen 4 Main Screen 5 Battery Status 6 Indirect Pythagoras Measuring 7 Area Volume Measuring 8 Single Continuous Measuring 9 Unit of Measure LCD Display 7349H English_Manuals 9 6 13 1 55 PM Page 5 ...

Page 6: ...ect the laser beam and lead to measurement errors Hazards of Use Be aware that errors in distance measurements may occur if the instrument is defective or has been dropped been misused or modified Note Conduct periodic test measurements to ensure the instrument is measuring accurately and consistently This is most important if the instrument has been exposed to abnormal use Always confirm accuracy...

Page 7: ...nstrument will not be used for an extended time remove the batteries to protect against corrosion To Power On the Unit Press the power on measure continuous measure button to turn on the unit The LCD and laser beam will turn on the unit will beep once To Power Off the Unit Press the clear power off button once to clear the previous mode The unit will beep once Hold the button for 3 seconds to powe...

Page 8: ...t and inches in fractions of 1 16 in Feet and inches in fractions of 1 8 in Feet and inches in fractions of 1 4 in Feet and inches in fractions of 1 2 in Meters m 2 To exit units of measure and enter the reference position press the button once to enter the reference setting or the button to begin operations 6 Using the Product Measurement Reference Position There are two reference positions for t...

Page 9: ...t will go to the sub screen 6 Point the laser beam to the next target and press the button again The new measurement will be displayed on the main screen and the prior measurement on the sub screen 7 This can be repeated over and over again 8 To clear push the button once and the unit will beep once 9 To power off press the button for 3 seconds The unit will give a long beep 2013 Johnson Level Too...

Page 10: ...urements after taking the first measurement press the function button once 2 The first measurement will move to the sub screen and the laser beam will be on The add sign by the main screen will be flashing 3 Point the laser beam to the next target and press the button 4 The first measurement will be displayed on the sub screen and the combined measurements will be displayed on the main screen 5 To...

Page 11: ...To subtract additional measurements press the button twice again The sign will be on and the combined measurements will move to the sub screen 6 Press the button and the new measurement will be displayed on the sub screen and total measurement on the main screen 7 Repeat as often as desired Area Volume Indirect Pythagoras Measurements 1 To move from line to area to volume to indirect measurements ...

Page 12: ... screen in square feet Area symbol will be flashing Volume Measurement Cube3 1 With the unit turned on hold the button until the volume symbol 3 dimensional icon is displayed 2 Press the button once to measure the width The bottom volume symbol line will be flashing 3 Press the button a second time to measure the length Right side volume symbol line will be flashing 4 Press the button a third time...

Page 13: ...e note the position of your hand when taking first measurement Do not move your hand when preparing to take the second measurement Simply pivot your wrist keeping instrument in same position to align the next target Then record next measurement 4 Press the button once to record the first measurement 5 Press the button a second time to record the second measurement 6 The sum of both indirect measur...

Page 14: ...factors to the quality of measurement indoors and outdoors Outdoor measurement capability may be limited due to sunlight UV ray interference Please note that in some situations the unit may have difficulty reading the surface you try to measure if lighting or sunlight is intense and or the surface being measured does not reflect the laser beam appropriately 7349H English_Manuals 9 6 13 1 55 PM Pag...

Page 15: ... Err06 Temperature is outside of working range Measure in an environment within specified working temperature range Err07 Ambient light is too strong Measure in a darker place shadow target Measurement Errors Error messages will appear if the unit s receiver is not getting a sufficient laser return signal Common surfaces that could cause an error reading Water or other fluids Translucent to clear ...

Page 16: ...ments verify that the instrument is in proper working order and take sample measurements to a known distance to verify accuracy To accurately measure from the rear of the instrument use a scrap piece of drywall or other flat material Extend the material off the corner and butt the LDM up to the material Then take measurement Place a white sheet of paper over the targeted measuring surface if error...

Page 17: ... x 32 x 22 mm Working Temperature 23 F to 104 F 5 C to 40 C Storage Temperature 4 F to 140 F 20 C to 60 C Auto Shut off Laser Approximately 30 seconds Auto Shut off Main Power Approximately 3 minutes IP Protection Class 54 The working range and accuracy is dependent on how well laser light is reflected from the surface for the target and with increased brightness of the ambient light intensity mea...

Page 18: ...nlevel com The limited warranty for each product contains various limitations and exclusions NOTE The user is responsible for the proper use and care of the product For further assistance or if you experience problems with this product that are not addressed in this instruction manual please contact our Customer Service Department In the U S contact Johnson Level Tool s Customer Service Department...

Page 19: ... product that is located inside the battery compartment door PLEASE NOTE THAT IN ADDITION TO ANY OTHER LIMITATIONS OR CONDITIONS OF JOHNSON LEVEL TOOL S LIMITED WARRANTY JOHNSON LEVEL TOOL MUST HAVE RECEIVED YOUR PROPERLY COMPLETED WARRANTY CARD WITHIN 30 DAYS OF YOUR PURCHASE OF THE PRODUCT OR ANY LIMITED WARRANTY THAT MAY APPLY SHALL NOT APPLY AND THERE SHALL BE NO WARRANTY 7349H English_Manuals...

Page 20: ...20 2013 Johnson Level Tool Rev 1 7349H English_Manuals 9 6 13 1 55 PM Page 20 ...