background image

©2011 Johnson Level & Tool - Rev. 1

1

6

Magnetic Digital Level

Model No.  40-6060

Instruction Manual

Congratulations on your choice of this 6

Magnetic Digital Level. We

suggest you read this instruction manual thoroughly before using the
instrument. Save this instruction manual for future use.

4595H-English_Manuals  4/8/11  9:31 AM  Page 1

Summary of Contents for 40-6060

Page 1: ... No 40 6060 Instruction Manual Congratulations on your choice of this 6 Magnetic Digital Level We suggest you read this instruction manual thoroughly before using the instrument Save this instruction manual for future use 4595H English_Manuals 4 8 11 9 31 AM Page 1 ...

Page 2: ...A Alkaline Batteries 3 Soft Sided Pouch 1 2 Features and Functions Angle inclination in 5 construction languages units of measure degrees percent mm m in ft in decimal in ft in fractional Small and handy Working range of angle measurement 4 x 90º 0º and 90º position of inclination is confirmed by a signal tone Automatic digit inversion for overhead measurements Hold function to freeze measurement ...

Page 3: ... 2011 Johnson Level Tool Rev 1 3 3 Location of Part Components LCD Display Battery Compartment 4595H English_Manuals 4 8 11 9 31 AM Page 3 ...

Page 4: ... cover Remove the old batteries and install the new batteries 3 Turn on the level to see if all functions are correct Note 1 Be sure to match up polarities when replacing the batteries 2 Always remove the batteries before storing the instrument IMPORTANT It is the responsibility of the user to verify the calibration of the instrument before each use 4595H English_Manuals 4 8 11 9 31 AM Page 4 ...

Page 5: ... capability to measure in Degrees Percentage of slope Millimeters per Meter Inches per Foot Slope Pitch in decimal form and Inches per Foot in fractions of an inch A symbol on the upper right of the screen will explain which MODE you are currently in Zero Calibration Horn Key Periodic checking should be conducted to this instrument If it is out of alignment recalibration will be necessary This key...

Page 6: ...hut off automatically if no operation is received within six minutes Low power Indication When voltage is low battery symbol will flash in the left LCD as shown below When this is flashing batteries need to be replaced Horn Function Push the Zero Horn key once to turn on the horn symbol should be displayed Push again to turn off Horn will start a slow beep at 10º or 17 5 and beep faster the closer...

Page 7: ...ol Rev 1 7 The figure below shows the left side of the digital level needs to be moved up to achieve level Shows that the digital level is level Shows the measurement of the slope 4595H English_Manuals 4 8 11 9 31 AM Page 7 ...

Page 8: ...cond degree value 3 Turn over the digital level in the same plane figure 3 wait 10 seconds and record the third degree value when it is stable 4 Rotate the digital level 180º in the same plane figure 4 wait 10 seconds and write down the fourth degree value when stable 5 Of the four degree readings if any two of the values have a differ ence over 0 1º the unit must have a new Zero plumb recalibrati...

Page 9: ...e the digital level 180º in the same plane figure 8 wait 10 seconds and write down the fourth degree value when stable 5 Of the four degree readings if any two of the values have a differ ence over 0 1º the unit must have a new Zero plumb recalibration Horizontal Calibration 1 Turn on the instrument and put it on a smooth and horizontal sur face figure 9 Press and hold in for 5 seconds the Zero Ca...

Page 10: ...til the LCD displays 0 4 After 10 seconds press the Zero key again until the LCD displays 1 5 Turn the digital level 180º on the same plane figure 12 wait 10 seconds and press the Zero key again until the LCD displays 2 6 The horizontal calibration is complete Figure 9 Figure 10 Figure 11 Figure 12 4595H English_Manuals 4 8 11 9 31 AM Page 10 ...

Page 11: ...ital level to the other vertical surface figure 14 wait 10 seconds and press the Zero key until the LCD displays 2 3 Turn the unit over still on the same plane making it upside down as in figure 16 then press the Zero key until the LCD displays 0 4 After 10 seconds press the Zero key again until the LCD displays 1 5 Turn the digital level back to the first vertical surface on the same benchmark pl...

Page 12: ...º for 1º and 89º Working Range 0º to 90º Power Supply 3 AAA alkaline batteries Battery Life Approx battery life 100 hours continuous use Dimensions 6 14 x 2 2 x 1 22 156 x 56 x 31mm Weight 0 66 lbs 0 3 Kg Working Temperature 14 F to 113 F 10 C to 45 C 4595H English_Manuals 4 8 11 9 31 AM Page 12 ...

Page 13: ...es when storing the unit for an extended time more than three months to avoid damage to the unit should the batteries deteriorate Always store the unit in its case when not in use Avoid getting the unit wet Keep the level dry and clean Remove any moisture or dirt with a soft dry cloth Do not use harsh chemicals strong detergents or cleaning solvents to clean the level 4595H English_Manuals 4 8 11 ...

Page 14: ...ins various limitations and exclusions NOTE The user is responsible for the proper use and care of the product It is the responsibility of the user to verify the calibration of the instrument before each use For further assistance or if you experience problems with this product that are not addressed in this instruction manual please contact our Customer Service Dept In the U S contact Johnson Lev...

Page 15: ... 2011 Johnson Level Tool Rev 1 15 4595H English_Manuals 4 8 11 9 31 AM Page 15 ...

Page 16: ...16 2011 Johnson Level Tool Rev 1 4595H English_Manuals 4 8 11 9 31 AM Page 16 ...