©2005 Johnson Level & Tool
Safety Mode (TILT)
1. After powering on the instrument and entering into
auto-level status, press the tilt button. When the
indicator lamp lights us (see figure), the instrument
enters into TILT mode. If the leveled instrument is
moved or bumped, the head will stop rotation and the TILT indicator
lamp will flash instead of the unit performing the auto-level function.
At this time, you must press the tilt button to quit safety mode and
enter into auto-level status.
2. Press the tilt button to quit safety mode and activate auto-level mode.
Slope Adjusting Function (SLOPE)
The function must be operated by the remote control (see operating
panel shown in fig.1).
1. Select slope adjusting direction
The first press of X/Y button will illuminate the X indicator lamp
(fig. 2) and you should then select the X-direction slope adjustment
(see below). The second press of X/Y button will illuminate the Y
indicator lamp (fig. 3) and you should then select the Y-direction
slope adjustment. The third press of the X/Y button will quit the
slope-adjusting function and enter the unit into auto-level status.
2. Adjust the slope angle
Press either of the two arrow
keys on remote control (fig.1) to
adjust slope angle.
Note:
A single press of either key
activates fine tuning while a
continuous pressing activates
quick adjustment.