background image

Specifications:

Model Part No. System Volts Banks

Output per 

Bank (amps)

Total Output 

(amps)

Input Cable Output Cable

Size L x W x H

Weight 

(lbs)

Input  Current            

(120VAC, 60Hz)

MK106D

1821065

12

1

6

6

18AWG - 6’

16AWG - 6’

8-3/4” x 4-3/4” x 3”

4.5

1A

7

9. TROUBLESHOOTING

 

PROBLEM:

Check Connection (Red) light comes on.

SOLUTION:

-Check polarity of leads to battery.

-Check connetions to battery and fuses in output cord.

-Check voltage at battery.  The bank will not charge a battery below 4 volts or above 18 volts.

-If still not working, call the Minn Kota Service Department at 1-800-227-6433.

PROBLEM:

Check Connection (Red) light is flashing.

SOLUTION:

-The temperature sensor in the output cord is damaged.  Check to make sure the output cord is not damaged.  If the output cord was  

  extended, check to make sure the procedure in Section 6 was followed.

-If still not working, call the Minn Kota Service Department at 1-800-227-6433.

PROBLEM:

Indicator lights will not illuminate.

SOLUTION:

-Check the AC power at the outlet.

-Make sure the GFCI(Ground Fault Circuit Interrupter) o the outlet has not tripped.

-Check the AC power at the end of the extension cord.

-If still not working, call the Minn Kota Service Department at 1-800-227-6433.

PROBLEM:

The red and green lights are flashing.

SOLUTION:

-Check to make sure there are not any loads on the battery

-Check the fluid in the battery and add fluid if necessary.

-If the voltage of the battery does not increase above 10.5 volts after 3 hours or does not increase to the absorption voltage of 14.4 volts in 20 hours, then  

 the bank will shut down and will not charge.  The battery should be tested.

-If still not working, call the Minn Kota Service Department at 1-800-227-6433.

Summary of Contents for MINN KOTA MK106D

Page 1: ...Y CHARGERS Models MK106D Service Information Please call our service department at 800 227 6433 if you have any problems with your battery charger A technical support representative will be happy to assist you Compliant with FCC Part 15 Class B ...

Page 2: ...ny way Do not disassemble the charger Incorrect reassembly may result in a risk of electric shock or fire To reduce risk of electric shock unplug the charger from outlet before attempting any maintenance or cleaning Disconnecting the leads will not reduce this risk To reduce to risk of shock or spark never touch the ring terminals together while the charger is plugged into an outlet or extension c...

Page 3: ...all battery manufacturers specific precautions however make sure to REPLACE ALL CELL CAPS after refilling so that water evaporation is avoided Water will evaporate over time if cell caps are not replaced after refilling For a battery without removable cell caps such as valve regulated lead acid batteries carefully follow manufacturer s recharging instructions NOTE The battery fluid level should be...

Page 4: ...se Mount the AC plug holder with four screws in a convenient dry site to prevent corrosion to the AC plug and to prevent the AC plug from making contact with the battery posts CONNECTING THE BATTERIES TO THE CHARGER FOLLOW THESE STEPS WHEN THE BATTERY CHARGER IS INSTALLED IN A BOAT OR VEHICLE A SPARK NEAR THE BATTERY MAY CAUSE BATTERY EXPLOSION TO REDUCE THE RISK OF A SPARK NEAR THE BATTERY 1 Posi...

Page 5: ...ng will be displayed on the charger A GREEN power light is lit to indicate AC power is applied Each bank has YELLOW GREEN and RED lights to indicate charging status and error conditions Minn Kota s Multi Stage Charging has three modes of operation that deliver a fast precise charge profile by automatically controlling current and voltage without overcharging your batteries Stage 1 Bulk Mode During...

Page 6: ...liance could void the user s authority to oper ate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not...

Page 7: ...ut cord was extended check to make sure the procedure in Section 6 was followed If still not working call the Minn Kota Service Department at 1 800 227 6433 PROBLEM Indicator lights will not illuminate SOLUTION Check the AC power at the outlet Make sure the GFCI Ground Fault Circuit Interrupter o the outlet has not tripped Check the AC power at the end of the extension cord If still not working ca...

Page 8: ...hould dispose of your waste equipment for recycling and recovery and or your European Union member state requirements please contact your dealer or distributor from which your product was purchased Tools required but not limited to Flat Head screw driver Phillips screw driver Socket set Pliers wire Cutters 8 ...

Page 9: ...ENTIAL OR SPE CIAL DAMAGES Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitations and or exclusions may not apply to you This warranty gives you spe cific legal rights and you may also have other legal rights which vary from state to state 2013 Johnson Outdoors Marine Electronics Inc ...

Reviews: