Time Fade

The control station is capable of fading from:
“OFF” 

“ON” 

“ON”      “OFF”

“OFF” 

“DIM” 

“DIM”        “OFF”

The control station is capable of pseudo fading from:
“DIM” 

“ON” 

“ON”      “DIM”

The control station automatically begins fading when a button is pressed. The button LED flashes 

on and off once per second to indicate fading.
NOTE:  Pressing a button or adjusting the master slider level while the control station is fading, 

cancels the fade and immediately activates the button pressed.

Set the Adjustable Time Fade

The time fade can be adjusted from 0 to 60 seconds. The factory default time fade is 5 seconds.
NOTE:  Be sure the local and remote lockout modes are deactivated before adjusting the time fade.
Procedure:

•  To set the adjustable time fade, press and hold the “ON” button for approximately 10 

seconds, until the “ON” LED extinguishes.

•  Release the “ON” button and count the number of times the “ON” LED flashes on.           

Each time the “ON” LED flashes on, 1 second of time fade is represented.

•  Once the required number of times the “ON” LED flashes on is counted, press the “ON” 

button to save the time fade and exit.

•  To set the time fade to zero (no fading), press and hold the “ON” button for approximately    

10 seconds, until the “ON” LED extinguishes. Release the “ON” button and immediately 

press the “ON” button again before the “ON” LED flashes on.

Set the Button LED Intensity

The button LED intensity can be adjusted to a preferred intensity level for various environments.
NOTE:  Be sure the local and remote lockout modes are deactivated before adjusting the button 

LED intensity.

Procedure:

•  To enter the button LED intensity adjust mode, press and hold the “ON” and “OFF” buttons 

at the same time for approximately 10 seconds, until all the button LED’s illuminate.

•  Press the “ON” button to increase the button LED intensity. Press and hold the “ON” button 

to accelerate the intensity adjustment.

•  Press the “OFF” button to decrease the button LED intensity. Press and hold the “OFF” 

button to accelerate the intensity adjustment.

•  Once the preferred button LED intensity has been set, press the “ON” and “OFF” buttons at 

the same time to exit the button LED intensity adjust mode and save the setting.

NOTE:  There is a minimum button LED intensity so the control station will always indicate its 

mode of operation/state.

Summary of Contents for CS-DMX Series

Page 1: ... Calgary Alberta Canada T2G 5M1 tel 403 287 8003 fax 403 287 9003 e mail info johnsonsystems com website www johnsonsystems com User Manual CS DMX Series Programmable Manual DMX Stations JOHNSON SYSTEMS INC www johnsonsystems com ...

Page 2: ... Secondary 3 6 9 or 12 Sliders 5 Control Station Security Feature 5 Power Supply Requirement 6 Control Station Wiring 6 DMX Input and Output Wiring 6 Wiring an Independent Control Station 7 Wiring a Single or Multiple Entrance Control Stations to a Master Control Station 7 Wiring Two or More Master Control Stations Together with Take Control 7 Wiring Two or More Control Stations Together with Mimi...

Page 3: ...tensity allow customization for demanding applications Durable powder coat finish is available in either black or white CS DMX Series Programmable Manual DMX Station Features Manual DMX at your fingertips Six models sizes available including two and three button entrance stations 512 DMX channels of control per station Multiple stations can be daisy chained on the same DMX line Digitally adjustabl...

Page 4: ...g Output DMX Output Range Calibration Jumper JP1 Security Enable Disable Jumper JP2 Factory Only Jumper s DMX Input Connector J1 DMX Output Connector J2 DMX Termination Jumper JP1 ON DIM and OFF Buttons With Integral LED s Master M Slider Infared LED Sensor Secondary 3 6 9 or 12 Sliders CS DMX Series Control Station Diagrams ...

Page 5: ...nnels patched to the sliders The OFF button corresponds with the RST reset connection on J1 and is optionally connected to other control stations for various applications NOTE The control station will still transmit DMX output levels at zero percent 00 in the OFF state Master M Slider The master slider controls the overall maximum DMX output level for the secondary sliders It has similar functiona...

Page 6: ...X in DMX IN and a 3 position breakaway connector used to transmit DMX out DMX OUT The DMX received on the DMX in if applicable connector is merged with the DMX generated by the control station and retransmitted through the DMX out connector Merged DMX data is highest takes precedence HTP for equivalent DMX control channels There is only a 1 packet 28msec delay in the retransmitted DMX from the ori...

Page 7: ...ly installed at an entrance location and used to trigger a master control station into the ON DIM or OFF state The entrance station s and master station mimic each other when a button is pressed Wiring between a single or multiple entrance stations and master station requires 2 conductors for V and common and 3 conductors for the switches ON DIM and RST 1 conductor for each switch function A singl...

Page 8: ...the control station from electrostatic discharge NOTE Ensure the back box mounting hole threads are not damaged Damaged threads on the back box can damage the threads on the mounting screws and cause stripping The back box threads can quickly be cleaned up by running a 6 32 tap through the mounting hole Be sure not to over tighten the mounting screws or this could result in stripping the back box ...

Page 9: ... is counted press the ON button to save the time fade and exit To set the time fade to zero no fading press and hold the ON button for approximately 10 seconds until the ON LED extinguishes Release the ON button and immediately press the ON button again before the ON LED flashes on Set the Button LED Intensity The button LED intensity can be adjusted to a preferred intensity level for various envi...

Page 10: ...ED flashes off for 0 1 seconds every 2 seconds to indicate remote lockout mode is activated Procedure To activate the remote lockout mode press and hold the DIM button for approximately 10 seconds until the DIM LED flashes off for 0 1 seconds To deactivate the remote lockout mode press and hold the DIM button for approximately 10 seconds until the DIM LED flashes off for 0 1 seconds Short Circuit ...

Page 11: ...www johnsonsystems com 11 CS DMX Series Typical Wiring Applications ...

Page 12: ...ang 2 button on off entrance station with adjustable on voltage for stand alone applications 5 x 18 AWG 1 gang 1 80 W x 2 75 H x 2 00 D 4 6cm x 7 0cm x 5 1cm CS SA ENT3B 1 gang 3 button entrance station w on preset and off 6 x 18 AWG 1 gang 1 80 W x 2 75 H x 2 00 D 4 6cm x 7 0cm x 5 1cm CS IPRO Hand held Infrared Station Programmer 2 75 W x 4 95 H x 1 00 D 70cm x 125cm x 25cm Wireless N A N A DMX ...

Reviews: