Angle Calibration

1.  Place level on a horizontal surface and apply power to product.

2.  With angle arm fully closed, press and hold Laser/Cal button until 

it shows a -1-.

3.  Fully open angle arm.

1150i-English_Manuals  6/10/16  9:56 AM  Page 13

Summary of Contents for 40-6065

Page 1: ...uction manual thoroughly before using the instrument Save this instruction manual for future use This is a Class IIIa laser tool and is manufactured to comply with CFR 21 parts 1040 10 and 1040 11 as well as international safety rule IEC 285 The laser also complies with EMC Test according to EN61000 6 3 2001 A11 2004 EN 6100 6 1 2011 EN 6100 4 2 EN 61000 4 3 EN 60825 FCC Test according to PART 15 ...

Page 2: ...Description Qty AA Alkaline Batteries 3 CR2032 Button Battery 1 Soft sided Pouch 1 Instruction Manual with Warranty Card 1 2 Features and Functions Displays angle and inclination simultaneously Angle measurements in degrees Angle inclination in 5 construction languages units of measure degrees percent mm m in ft in decimal in ft in fractional Automatic digit inversion for overhead measurements Wor...

Page 3: ...anner that may cause someone to unintentionally look into the laser beam Serious eye injury may result Do not operate the tool in explosive environments i e in the presence of gases or flammable liquids Keep the laser tool out of the reach of children and other untrained persons Do not attempt to view the laser beam through optical tools such as telescopes as serious eye injury may result Always t...

Page 4: ...4 2016 Johnson Level Tool Rev 3 4 Location Content of Warning Labels 1150i English_Manuals 6 10 16 9 56 AM Page 4 ...

Page 5: ... 2016 Johnson Level Tool Rev 3 5 5 Location of Part Components LCD Displays Laser Point Panel Angle Level Arm Locking Screw Battery Compartment 1150i English_Manuals 6 10 16 9 56 AM Page 5 ...

Page 6: ...ument is not going to be used for a long time Replacement Installation of Button Battery 1 If the angle LCD displays Erro it is necessary to replace the button battery 2 Remove the 3 screws on the button battery cover and open battery compartment 3 Replace the old battery with a new battery 4 Put the battery cover back on 5 Check angle calibration IMPORTANT It is the responsibility of the user to ...

Page 7: ...rn on and the laser icon will appear on the LCD The instrument will also beep once Press and release this key again and laser beam will turn off and laser icon will disappear on the LCD Note The instru ment must be turned on for the laser beam to work Press and hold this key more than one second and the unit will enter angle calibra tion mode See Self Check and Calibration section Display for Angl...

Page 8: ... a short press will turn on the sound function and the sound icon will appear on the LCD Press and release the key to turn off the sound function and sound icon will disappear on the LCD The instrument will beep once when turning the sound on and off The level will beep faster when the level gets closer to 0 and 90 10 0 and 80 90 when the LCD displays 0 or 90 there will be a continuous tone Press ...

Page 9: ...ery power is low Replace the batteries as soon as possible Incline Indication Arrows The following figure shows that moving the angle level according to the indicated direction arrows is necessary if you want to position the level to horizontal or vertical The following figure shows that the level is level or plumb Mode Battery Symbol Incline Indication Incline Indication 1150i English_Manuals 6 1...

Page 10: ...to 180º then tighten the locking screw clockwise You can lock the arm at any angle within the range of 0º to 180º The laser point will be parallel with the reference plane Measuring the inclining angle to the level plane Reference plane Display window 1150i English_Manuals 6 10 16 9 56 AM Page 10 ...

Page 11: ...orizontal Calibration Check Put the angle level on a smooth level plane and observe the LCD display Note the reading after ten seconds Then rotate the angle level 180 on the same plane After another ten seconds note the second angle reading Calibration is necessary if the difference between the two measuring readings is over 0 2 IMPORTANT It is the responsibility of the user to verify the calibrat...

Page 12: ...vel on a flat surface and press the CAL button 0 will be displayed Wait 10 seconds 2 Press the CAL button again and 1 will be displayed Turn the level 180º on the same surface Wait another 10 seconds 3 Press the CAL button once again If it beeps once the calibration is completed it is correct If it beeps twice the calibration is not completed and the procedure should be repeated If it continues to...

Page 13: ...3 Angle Calibration 1 Place level on a horizontal surface and apply power to product 2 With angle arm fully closed press and hold Laser Cal button until it shows a 1 3 Fully open angle arm 1150i English_Manuals 6 10 16 9 56 AM Page 13 ...

Page 14: ...n again to display 2 After about 2 seconds display should revert back to measuring mode displaying 180 0 5 The angle calibration is completed Verify calibration by closing angle arm Note that right display reads 0 0 1150i English_Manuals 6 10 16 9 56 AM Page 14 ...

Page 15: ...º Accuracy Angle 0 1º Working Range 0º to 90º Resolution 0 1º or 0 1 Accuracy 0 1º for 0º and 90º and 0 2º for 1º to 89º Power Supply 3 AA alkaline batteries and 1 3v CR2032 lithium battery Battery Life Approx battery life 70 hours continuous use Dimensions 23 6 x 2 48 x 1 57 600 x 63 x 40mm Weight 2 64 lbs 1 2kg Working Temperature 14 F to 113 F 10 C to 45 C 1150i English_Manuals 6 10 16 9 56 AM ...

Page 16: ...the batteries when storing the unit for an extended time more than three months to avoid damage to the unit should the batteries deteriorate Always store the unit in its case when not in use Avoid getting the unit wet Keep the laser unit dry and clean especially the laser output window Remove any moisture or dirt with a soft dry cloth Do not use harsh chemicals strong detergents or cleaning solven...

Page 17: ...Contact one of our service centers for all non warranty repairs A list of service centers can be found on our web site at www johnsonlevel com or by calling our Customer Service Department Contact our Customer Service Department for Return Material Authorization RMA for warranty repairs manufacturing defects only Proof of purchase is required NOTE The user is responsible for the proper use and car...

Page 18: ...that is located inside the bat tery compartment PLEASE NOTE THAT IN ADDITION TO ANY OTHER LIMITATIONS OR CONDITIONS OF JOHNSON LEVEL TOOL S LIMITED WARRANTY JOHNSON LEVEL TOOL MUST HAVE RECEIVED YOUR PROPERLY COMPLETED WARRANTY CARD AND PROOF OF PURCHASE WITHIN 30 DAYS OF YOUR PURCHASE OF THE PRODUCT OR ANY LIMITED WARRANTY THAT MAY APPLY SHALL NOT APPLY AND THERE SHALL BE NO WARRANTY 1150i Englis...

Page 19: ...button battery CR2032 If laser is out of calibration or numbers are inverted confirm that the unit is not in hold mode If arrows are blinking on each side of the digital readout press the hold function before attempting calibration Follow the calibration procedure in the user manual If laser will not calibrate follow the calibration procedure in the user manual rotate the level 180 do NOT flip it ...

Page 20: ...20 2016 Johnson Level Tool Rev 3 1150i English_Manuals 6 10 16 9 56 AM Page 20 ...

Reviews: