Johnson Health Tech. Co., Ltd.
Anomaly
code
Code description
Cause of anomaly
Countermeasures
0F
Inconsistency
between manual
controller model
and master
control panel
model
1. Inconsistency between
manual controller
model and lower
control panel
2. Inconsistency of
software versions
1. Confirm manual controller model
2. Replace with correct model software and
then confirm if the machine is normal
3. Replace the lower panel and then confirm if
the machine is normal
4. Ask for assistance of original factory
90
Communication
error
Communication
timeout
between manual
controller and lower
control panel
1. Confirm if connection between manual
controller and lower control panel is normal
2. Update software and then confirm if the
machine is normal
3. Replace the manual controller then confirm
if the machine is normal
4. Replace the lower panel and then confirm if
the machine is normal
5. Ask for assistance of original factory
3-1. Error code (0F, 90)