Feel the resistance increase/decrease suddenly or feel no
resistance
(JPC/B/S)
Possible causes:
1.
Console is damaged
or the console cable
is not connected
properly
2.
Console cable is
damaged.
3.
Control board is
damaged.
4.
Generator is
damaged.
5.
Alignment of the
sensor
(for JPS)
6.
Sensor is damaged
(for JPS)
7. Gap between the
electromagnet and the
copper disc of the
generator is too wide.
Fix:
1.
Remove the console and check if the console
cable has been connected properly.
2.
Console cable is damaged, replace it with a new
one.
3.
Remove the side covers of the fitness and check
if the terminal of the control board has been
connected properly. Control board is damaged,
replace it with a new one.
4.
Generator is damaged, replace with a new one
5.
Check if the sensor is positioned correctly.
u
Re-align the sensor to the correct position
6.
Sensor is damaged, replace it with a new one
7.
(1)Loosen the assembly screws of electromagnet
(2) With a c-vice press the electromagnet to
narrow the gap then check again.
.
2-4 Revision: 1.0 Date: 2001/06/01
Summary of Contents for JAR-5100
Page 1: ...o JPB 5100 o JPS 5100 o JAR 6000 o JPC 5100 o JPE 5100 o JAR 5100 ...
Page 5: ...SECTION 1 WIRING DIAGRAM Revision 1 0 Date 2001 06 01 ...
Page 11: ...JPC B 5100 WIRING DIAGRAM 1 6 Revision 1 0 Date 2001 06 01 ...
Page 12: ...JPS 5100 WIRING DIAGRAM 1 7 Revision 1 0 Date 2001 06 01 ...
Page 13: ...JAR 5100 WIRING DIAGRAM 1 8 Revision 1 0 Date 2001 06 01 ...
Page 14: ...JPE 5100 WIRING DIAGRAM 1 9 Revision 1 0 Date 2001 06 01 ...
Page 35: ...SECTION 3 PARTS REPLACEMENT PROCEDURE Revision 1 0 Date 2001 06 01 ...
Page 72: ...SECTION 4 PREMENTIVE MAINTENANCE Revision 1 0 Date 2001 06 01 ...
Page 76: ...SECTION 5 SERVICE FORM Revision 1 0 Date 2001 06 01 ...