CHAPTER 3: Troubleshooting
3.3.6 TROUBLESHOOTING – NO RESISTANCE OR INCORRECT RESISTANCE
Symptom
:
1. The resistance cannot be adjusted during exercise.
2. The resistance is reverse or much too heavy.
Solution (For A30)
:
1. Turn on the console and check the ECB motor.
In resistance level 1, the head of steel rope directs to top right side (around 45 degree).
If the head of steel rope points to bottom left side, the resistance will be reverse. Adjust the head of steel
rope to the correct position.
Notes: in the highest resistance level, the cable should have no tension (see ECB motor replacement
section).
2. Press key “+” or “
↑
”to adjust the resistance.
A) If ECB motor cannot move,
the resistance will not be changed. The ECB motor or console cable is
defective. Check the console cable inserted in ECB motor. Re-connect the console cable first, if still not
working, test cable for damage. If tests good, replace the ECB motor, make sure both cable ends are
seated properly.