background image

Handheld Optical Light Source-JW3116

 

 

Shanghai Joinwit Optoelectronic Co.,Ltd.                                               

 

 
 
 
 

 
 

Safety Sign: 

 

When using the optical power meter, always take bask safety precautions to reduce the harm for 
the testers, and injury to persons. All the safety sign may not mark in this manual.   

Warning

Prohibited misconduct and operation, to prevent any improper conduct and 

operation of the damage.   

 

Notice

  notic the important information, notification, and referencs, thse notice 

information should be understand. 

 

Safety sign on the instrument

 

WEEE  Sign

Users  of  electrical  and  electronic  equipment  from  private  households 

should have the possibility of returning WEEE at least free of charge

.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for JW3116

Page 1: ...countries with all rights reserved No part of this publication may be reproduced stored in a retrieval system translated transcribed or transmitted in any means manual electric electronic electromagnetic or otherwise without prior explicit written permission of Joinwit Optoelectronic Technology Co Ltd The information contained in this document is assumed to be correct and current The manufacturer ...

Page 2: ...ty sign may not mark in this manual Warning Prohibited misconduct and operation to prevent any improper conduct and operation of the damage Notice notic the important information notification and referencs thse notice information should be understand Safety sign on the instrument WEEE Sign Users of electrical and electronic equipment from private households should have the possibility of returning...

Page 3: ... batteries and kept separate to avoid instrument damage caused by battery leakage If leakage occurred Please do not touch 3 To prevent electric shock do not open the product case only the authorized qualified professionals can do the maintenance Do not expose the testers to rain or wet conditions to avoid the risk of fire or electric shock 4 Instruments used LCD screen Do not fall the instrument I...

Page 4: ...Front 3 4 2 Left Side 4 4 3 Top 5 4 4 Backside 6 Chapter 5 Operation Instruction 6 5 1 Ways of power supply 6 5 2 Power on the laser source 8 5 3 Backlight Setting 9 5 4 Output Power 10 5 5 Wavelength Automatic Identification 12 5 6 Frequency detection 12 5 7 Power Off 13 Chapter 6 Trouble shooting 13 Chapter 7 General Maintenance 14 Chapter 8 Quality Warranty 14 ...

Page 5: ...6 can provide 1 4 wavelength with stable output power and featured with continuous adjustable output power The Intelligent backlight control function can save the power JW3116 have smooth appearance good touching and friendly design which can meet clients largest requirements Features Wave ID information can be transmitted when used with JW3216 Optical Power Meter Tone generation 270HZ 330HZ 1KHZ ...

Page 6: ...kaline Battery 3 AA 1 5V Power Supply Adaptor V 8 4 Battery Operating time h 45 Operation Temperature 10 60 Storage Temperature 25 70 Outline size mm weight 175 90 44 5 255g Model JW3116 Operating wavelength nm 1310 1550 others specify on requests Applicable fiber SM MM Laser type FP LD others specify on requests Output Power dBm 7 adjustable Adjustable Step dBm 0 5 Adjustable Range 5 Stability dB...

Page 7: ...wer meter will enter into this mode 2 Wavelength Selection After on the tester first press to laser on then press to select the wavelength and display the current wavelength on the left top of the screen 3 backlight control JW3116 have two type of backlight control press to choose one mode LDR the intelligent backlight control mode Power meter will off on the backlight within 15second based on the...

Page 8: ...the screen AU display when enter into the wavelength identify mode 7 output power up Up the output power 8 B L SET backlight indicator Indicate the backlight control mode when the indicator green which means LDR in the Intelligent back light control mode when the indicator red which means the backlight in the key control mode 9 LDR Intelligent backlight controller In the intelligent backlight cont...

Page 9: ...ptical connector is FC PC 4 4 can connect with FC PC adaptor 4 4 FC PC connector Notice the tinny dust on the connector will affect the accurate of the measurement value so please clean the connector and the patch cord end face before do the test Use the alcohol and the cotton swab to clean the connector Dip the cotton swab with alcohol insert the cotton swab in the connector slightly rotating the...

Page 10: ...their positive and negative connector orientation The negative battery connector should be against the spring And do recycle the battery do not throw the battery to the dustbin or that will happen the dangerous Chapter 5 Operation Instruction 5 1 Ways of power supply JW3116 can be either battery powered or AC adaptor powered giving total flexibility for most testing sites and situations 5 1 1 AA b...

Page 11: ...ies making a note of their positive and negative connector orientation The negative battery connector should be against the spring Insert 3 new 1 5VV AA battery Refit the battery compartment cover The clip fastener should click shut Notice Make sure that you insert the batteries with their positive and negative connectors correctly aligned 5 1 2 Power Supply Unit When the battery is used out can u...

Page 12: ...with the tester use other kind of PSU may cause damage for the instruments 5 2 Power on the laser source First of all insert the battery or the PSU press on the tester at this time the laser are still off the opening displaying as 5 5 5 5 AC power supply sign Electricity indicate Laser off Rated power Power saving mode Auto off Power Supply Power Plug AC adaptor Selected wavelength ...

Page 13: ...ontrol mode 5 3 1 LDR Intelligent backlight control mode Long press B L SET is green 6 6 after 10 seconds the green indicate off the LDR the controller will automatically adjust the backlight within 15 seconds with the outside light which to save the power 5 6 5 3 2 Choose the key control backlight mode Long press B L SET indicator turns to red 6 7 enter into key control backlight mode after 10 se...

Page 14: ...the correct patch cord are connected 5 4 2 Laser on the light source When open JW3116 the laser source still laser off only after press or can laser on the diode 5 8 5 9 Laser off 5 8 Press to laser on the diode Laser off 5 9 press to laser on the diode Notice To avoid risk of serious eye damage Do not look into the interfaces at any time 5 4 3 Select the wavelength Laser on output wavelength 1310...

Page 15: ...elength can adjust the output power within the range 5 12dBm and also can load with the output frequency Press to down the output power while to load the output frequency 5 11 5 13 5 11 5 12 press down the output power 5 13 press to load the frequency For the same principle press to up the output power while to load the output frequency Output wavelength ...

Page 16: ...ptical power meter also will be changed automatically according to light source Please refer to below figure 5 14 for easy understanding Exit Wave ID mode Hold down again to exit Wave ID mode from power meter and hold down again to exit Wave ID mode from light source JW3116 Light source JW3216 Power Meter 5 14 5 6 Frequency detection Connect JW3116 light source with its same serials power meter JW...

Page 17: ...ne batteries or is with power supply adaptor directly Manual power off Under any operation mode hold down for a few seconds to turn the unit off Note With either power off operation the unit will store the last calibration wavelength and backlight control mode automatically which will be the default setting when user turns unit on next time Chapter 6 Trouble shooting Problems Possible cause Soluti...

Page 18: ...r or replace free of charge But the freight cost and related taxes will be shared by both parties Joinwit will pay the shipping cost from customer side to Joinwit and pay the import taxes in China Customer will pay the shipping cost from Joinwit to customer side and its local import taxes accordingly 3 This warranty is limited to defects in workmanship and materials and does not cover damages from...

Page 19: ...about updates modifications and recalibration CUSTOMER SERVICE Phone 86 21 51591648 Fax 86 21 51591519 info joinwit com www joinwit com Warranty Registration Card Serial Number Model Number Date of Purchase Company Name Company Address TEL FAX E mail Note Please fax this note within one month from the date of receiving units Do you have any comments on the quality of this product or the service fr...

Reviews: